Georgia Class I Electrical Contractor Exam
Newest (2026 Update) Actual Practice
Questions – Set 100 Most Common Exam
Questions And Answers In Details 100%
Verified Exam
1. What is the minimum burial depth for rigid metal conduit (RMC) under a
residential driveway according to the NEC?
A. 6 inches
B. 12 inches
C. 18 inches
D. 24 inches
✔ Correct Answer: C (18 inches)
Explanation: NEC Table 300.5 requires a minimum cover of 18 inches for
RMC under residential driveways to ensure protection from physical
damage.
2. A 20-amp branch circuit supplies continuous lighting. What is the maximum
allowable load?
A. 16 amps
B. 18 amps
C. 20 amps
D. 24 amps
✔ Correct Answer: A (16 amps)
Explanation: Continuous loads must not exceed 80% of the circuit rating
(20A × 0.8 = 16A) per NEC 210.20(A).
3. What is the minimum size copper grounding electrode conductor for a 200-
amp service?
A. #8 AWG

, B. #6 AWG
C. #4 AWG
D. #2 AWG
✔ Correct Answer: B (#6 AWG)
Explanation: NEC Table 250.66 specifies #6 copper for grounding electrode
conductors connected to rod electrodes.
4. Which NEC article covers branch circuits?
A. Article 110
B. Article 210
C. Article 220
D. Article 250
✔ Correct Answer: B (Article 210)
Explanation: NEC Article 210 governs branch circuits, including ratings,
loads, and installation requirements.
5. What is the maximum number of 12 AWG conductors allowed in a 4-inch
square box 1.5 inches deep?
A. 6
B. 8
C. 9
D. 10
✔ Correct Answer: B (8)
Explanation: Box fill calculations per NEC 314.16 limit conductor count
based on cubic inch volume.
6. A motor draws 30A full-load current. What size branch circuit conductor is
required?
A. 30A
B. 36A
C. 37.5A
D. 40A
✔ Correct Answer: C (37.5A)

, Explanation: Conductors must be sized at 125% of motor FLC (30 × 1.25 =
37.5A) per NEC 430.22.
7. What type of conductor insulation is rated for wet locations?
A. NM
B. THHN
C. THWN
D. XHHW
✔ Correct Answer: C (THWN)
Explanation: THWN insulation is specifically rated for wet conditions.
8. What is the required GFCI protection for receptacles in bathrooms?
A. Optional
B. Required only for 20A
C. Required for all
D. Only for new construction
✔ Correct Answer: C (Required for all)
Explanation: NEC 210.8(A) requires GFCI protection for all bathroom
receptacles.
9. What is the minimum working clearance in front of electrical equipment
operating at 120V?
A. 24 inches
B. 30 inches
C. 36 inches
D. 48 inches
✔ Correct Answer: C (36 inches)
Explanation: NEC 110.26 requires a minimum of 3 feet clearance.
10.What is the purpose of bonding?
A. Increase voltage
B. Reduce resistance
C. Ensure electrical continuity
D. Increase current flow

Written for

Institution
Georgia Class I Electrical Contractor
Course
Georgia Class I Electrical Contractor

Document information

Uploaded on
June 24, 2026
Number of pages
26
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

$22.99
Get access to the full document:

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
elitemindsA Teachme2-tutor
View profile
Follow You need to be logged in order to follow users or courses
Sold
44
Member since
6 months
Number of followers
2
Documents
2668
Last sold
5 days ago
Ultimate Exam Prep Vault elitesmindsA

Every document is carefully organized, updated, and created to save you time and increase your chances of success. expect Practice questions to test understanding Exam-focused study structure for efficient preparation Easy-to-review format for fast learning Whether you're preparing for a state contractor license, engineering certification, HVAC exam, environmental exam, or trade qualification — I provide focused, exam-ready resources to help you pass. Study smart. Prepare strategically. Pass confidently.

Read more Read less
4.1

9 reviews

5
4
4
2
3
3
2
0
1
0

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions