Written by students who passed Immediately available after payment Read online or as PDF Wrong document? Swap it for free 4.6 TrustPilot
logo-home
Document preview thumbnail
Preview 4 out of 35 pages
Exam (elaborations)

MEDICAL GAS 6010 INSTALLERS PRACTICE TEST FOR ASSE 6010 CERTFICATION PREP EXAM WITH ACTUAL CORRECT QUESTIONS AND VERIFIED DETAILED ANSWERS|CURRENTLY TESTING VERSION|ALREADY GRADED A+|EXPERT VERIFIED FOR GUARANTEED PASS 2026|

Document preview thumbnail
Preview 4 out of 35 pages

MEDICAL GAS 6010 INSTALLERS PRACTICE TEST FOR ASSE 6010 CERTFICATION PREP EXAM WITH ACTUAL CORRECT QUESTIONS AND VERIFIED DETAILED ANSWERS|CURRENTLY TESTING VERSION|ALREADY GRADED A+|EXPERT VERIFIED FOR GUARANTEED PASS 2026|

Content preview

MEDICAL GAS 6010 INSTALLERS PRACTICE
TEST FOR ASSE 6010 CERTFICATION PREP
EXAM WITH ACTUAL CORRECT QUESTIONS
AND VERIFIED DETAILED
ANSWERS|CURRENTLY TESTING
VERSION|ALREADY GRADED A+|EXPERT
VERIFIED FOR GUARANTEED PASS 2026|

A master alarm panel shall be located in the office or work space of the individual responsible
for the maintenance of the medical gas piping system. The other master alarm shall be located
in _ ?

A) an area of continuous observation

B) the nurse station

C) the office of the authority having jurisdiction

D) the source equipment room

A) an area of continuous observation

A master alarm system shall consist of two or more alarm panels, one of which can be
substituted by a _ ?

A) area alarm

B) centralized computer system

C) fire alarm

D) security system

B) centralized computer system

Where an initiating device is remote from the building a _ set of wires shall be permitted to
connect the initiating device to a junction box where the wiring first enters the building?

A) double

B) duplex

1|Page

,C) single

D) triple

C) single

Two master alarm panels shall be wired independently to the initiating device for each signal,
and a single initiating device shall be permitted to actuate _ ?

A) a computer

B) a single master alarm panel

C) area alarm panels

D) multiple master alarms panels

D) multiple master alarms panels

When a medical gas system is supplied by a manifold or other alternating-type bulk system, the
_ alarm system shall activate when, or just before, changeover occurs?

A) area

B) local

C) master

D) security

C) master



The master alarm system shall activate when the main line of the medical-surgical vacuum
system drops to or below _ in. HgV?

A) 10

B) 12

C) 30

D) 32

C) 12

A signal from each local alarm system shall be connected to the _ alarm panels to indicate that a
problem is present with the source equipment?


2|Page

,A) area

B) fire

C) master

D) warning

C) master

The medical air dew point high alarm from each compressor site will indicate at the master
alarm panels when the line pressure dew point is greater that _ *F?

A) +22

B) +32

C) +35

D) +44

C) +35

The instrument air dew point high alarm from each compressor site will indicate at the master
alarm panels when the line pressure dew point is greater than _ *F?

A) -22

B) -32

C) -35

D) -44

A) -22

Area alarm panels for medical gas systems shall indicate when line pressure in the area being
monitored increases or decreases _ % from normal operating pressure?

A) 10

B) 15

C) 20

D) 25

C) 20



3|Page

, In positive pressure systems area alarm sensors for vital life support and critical care areas shall
be located on which side of the zone valve box assemblies?

A) main line side

B) patient or use side

C) source side

D) upstream side

B) patient or use side

Areas for anesthetizing gas delivery shall have area alarm pressure sensors installed on the _
side of the individual room zone valve box assembly?

A) in

B) patient

C) source

D) source or patient

D) source or patient

If there is more than one source equipment location in a facility, it shall be necessary for each
location to have separate alarms at the _ panels?

A) area

B) fire

C) master

D) security

C) master

High carbon monoxide levels in a medical air system shall be indicated at each local alarm. The
alarm shall activate at _ ppm or higher?

A) 10

B) 20

C) 100

D) 1000


4|Page

Document information

Uploaded on
June 13, 2026
Number of pages
35
Written in
2022/2023
Type
Exam (elaborations)
Contains
Questions & answers
$17.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Drgary
4.6
(1402)
Sold
532
Followers
217
Items
3285
Last sold
1 day ago


Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions