ASMIRT – MRI Accreditation Exam
With Questions And Answers Updated
2026/2027|Graded A+

To achieve T1 weighting in a GRE sequence, what parameters should be set? - ANSWER>• T1 Weighting


in GRE


Large Flip angle 70-110 degrees


Short TE 5-10ms


Short TR < 50ms




To achieve T2 weighting in a GRE sequence, what parameters should be set? - ANSWER>T2* Weighting in


GRE


Small flip angle 5-20 degrees


Long TE 15-25ms


Short TR minimum possible depending on number of slices as the small flip angle ensures rapid T1


recovery

,To achieve PD weighting in a GRE sequence, what parameters should be set? - ANSWER>PD Weighting in


GRE Small flip angle 5-20 degrees Short TE 5-10ms Short TR minimum possible depending on number of


slices as the small flip angle ensures rapid T1 recovery




What is steady state? - ANSWER>This is the condition that applies when the TR used is shorter than the


T1 and the T2 of the tissue. There will not be enough time for the transverse magnetization to have


decayed away before the next RF pulse is applied. Each RF pulse produces an FID, each pair of pulses


produces a Hahn echo, and stimulated echoes arise from each set of three or more pulses. If the TR is


short enough, the tails of the FID's and the spin echoes merge to produce a continuous signal of varying


amplitude. The signal contains both FID and spin-echo components, with the TR being equal to the TAU


of the spin-echo




Explain how the residual transverse magnetization is can be removed in a steady state sequence? -


ANSWER>The use of short TR intervals creates the steady state condition, but with these sequences the


residual transverse magnetization is deliberately removed or 'spoiled' before the next excitation pulse.


Spoiling is done by;


• Gradient spoiling, where a gradient of varying amplitude is turned on just before the next RF pulse.


(Siemens' Flash)

, • RF spoiling, where the phase of the RF is changed with each excitation and the receiver locks on only to


the phase of the preceding pulse. (GE's SPGR




What are gradient echo incoherent/spoiled gradient echo sequences usually used to for in terms of


weighting - ANSWER>These sequences are used to produce rapid T1 weighted images. e.g. breath-hold


liver studies. Only the FID is re-phased - the spin-echo is spoiled and not sampled.




For GRE incoherent T1 weighted scans the following parameters are suggested - ANSWER>•Flip angle 30-


45 degree


•Short TE : minimum possible: often two are used for in and out of phase (minimum TE ensures minimal


T2*) •Short TR : 20-50ms




How is a coherent gradient echo sequence achieved? - ANSWER>Short TR values ensure that the steady


state is achieved with these sequences. The transverse magnetization left over at the time of the next


excitation pulse is kept coherent using a re-winder gradient after readout. This compensates for the


dephasing which occurs due to the phase encoding process.

Document information

Uploaded on
June 12, 2026
Number of pages
24
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$8.89

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Sold
0
Followers
0
Items
197
Last sold
-



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions