Tap on AVAILABLE IN BUNDLE / PACKAGE DEAL to unlock free bonus exams — save more while getting everything you need. The NGWA Water Systems General Certification Exam Actual Questions and Answers (Latest Update This Year) is a professional certification exam preparation resource designed to help candidates develop competency in groundwater systems, water well operations, and water systems installation and maintenance within the water supply and well drilling industry. This exam preparation material is structured to align with standards and best practices associated with the National Ground Water Association, focusing on safe, efficient, and environmentally responsible water system design, installation, and maintenance. The content emphasizes core groundwater and water systems principles, including well construction, pump systems, aquifer behavior, water quality basics, system components, pressure tanks, and distribution systems used in residential, agricultural, and commercial water supply applications. It also covers installation and maintenance procedures, including pump selection, system sizing, piping layout, pressure testing, troubleshooting system failures, and routine maintenance practices to ensure reliable and continuous water supply performance. A significant focus is placed on regulatory compliance and safety standards, including groundwater protection rules, well construction regulations, sanitation requirements, cross-connection control, and environmental safeguards to protect public health and water resources during system installation and operation.

Show more Read less
Institution
Exmm
Course
Exmm

Content preview

Page 1 of 162




NGWA Water Systems General Certification Exam
ACTUAL QUESTIONS AND ANSWERS LATEST
UPDATE THIS YEAR
NGWA Water Systems General Certification Exam
Point-Form Exam Coverage (Based on NGWA Core Competencies & 2024 Exam Outline)
Based on the National Ground Water Association (NGWA) Water Systems General Certification exam
blueprint, the exam covers the following major domains and industry standards, including NGWA's
"Certified Contractors Code of Excellence" .
Regulatory & Safety Foundation (10-15%)
• Safe Drinking Water Act (SDWA)
• Ground Water Rule (GWR) – requires sanitary completion and source water monitoring
• National Primary Drinking Water Regulations (NPDWR) – enforceable standards
• National Secondary Drinking Water Regulations – non-enforceable aesthetic guidelines
• OSHA 1926 Subpart P – trenching and excavation safety
• Lock-out/Tag-out (LOTO) – required when servicing pumps
• Confined space entry – atmospheric testing requirements
Well Construction & Development (20-25%)
• NGWA "Contractors Code of Excellence": install casing to at least 18 ft depth, surface seal,
sanitary well cap, pitless adapter
• Grouting requirements: Bentonite (minimum 20% solids for well seal)
• Surface seal: Minimum 18 ft depth; annular space grouted at least 10 ft for confined aquifers
• Sanitary well cap – prevents surface water entry
• Pitless adapter – eliminates frost heave, allows below-frost-line connection while maintaining
sanitary seal
• Annular space grouting to prevent vertical migration of contaminants
• Gravel pack design for sand control (filter pack for naturally unstable formations)
• Well development methods: surging (most effective for fine sand), air lift, overpumping, bailing
• Screen types: continuous slot (most open area), slotted casing, wire wrap, louvered
Pump Systems & Hydraulics (20-25%)
• Pump types: Submersible pump (most common for water wells), line shaft turbine, jet pump
(shallow and deep)
• Pump affinity laws: Flow (Q) varies directly with speed (N); Head (H) varies with N²; Power (P)
varies with N³
• Total Dynamic Head (TDH) = Static Lift + Friction Loss + Pressure Head (delivery pressure, if any)
• NPSH (Net Positive Suction Head) – critical for centrifugal pumps; not applicable to submersibles
• Motor sizing: 1 HP = 746 watts; service factor = ability to run above rated HP intermittently
• Cable sizing: voltage drop limits (max 3-5% for motors)
• Check valves – prevent backflow; required at pump discharge
• Torque arrestors – prevent twisting in the well
• Flow meters – required for compliance monitoring
Water Quality & Treatment (15-20%)
• Common contaminants: Iron, manganese, hardness, hydrogen sulfide (rotten egg odor)
• Treatment methods: Iron filtration (oxidation + filtration); Water softeners (ion exchange)

, Page 2 of 162



• Disinfection: Chlorination (shock chlorination for new wells, maintenance, after repairs); UV
disinfection (requires clear water)
• Reverse osmosis (RO) – removes TDS, nitrates, arsenic; produces wastewater
• Distillation – energy-intensive, removes most contaminants
• Corrosive water – addressed by pH adjustment or neutralizing filter (calcite)
• Coliform bacteria – causes gastrointestinal illness; requires disinfection
• Manganese – brown/black staining; lower secondary MCL than iron
• Aeration – removes hydrogen sulfide, radon, volatile organics, iron
• Bacterial iron – iron bacteria; requires disinfection and physical removal
• Filtration – turbidity removal
System Maintenance & Troubleshooting (15-20%)
• Pressure switch settings: Common 20/40, 30/50, 40/60 psi (typical differential of 20 psi)
• Pressure tank – provides drawdown volume; prevents short cycling
• Low yield troubleshooting: Pump cycles on/off rapidly (short cycling) → check pressure tank air
charge, bladder, or possible low yield
• Pump not delivering water: Check power, pressure switch, check valve, pump protection devices
(overload, low water cut-off)
• Air-locked pumps – common after repair, need to bleed air from discharge
• Galvanic corrosion – occurs when dissimilar metals are connected (use dielectric unions)
• Sand in water – well screen failure, gravel pack collapse, or overpumping
• Water level measurement – using electric sounder or air line
• Specific capacity = yield (gpm) / drawdown (ft) – declines with well age
Business & Professional Practice (5-10%)
• Customer service: written estimates, contracts, warranties
• NGWA Code of Excellence – ethical standards, transparency, responsible groundwater
stewardship
• Permit requirements – vary by state/local jurisdiction; contractor responsible for compliance




Question 1


A well driller is installing a new residential water well in an area with a shallow water table. According to


the NGWA Code of Excellence, what is the minimum depth to which casing must be installed to provide


a sanitary seal?


A) 10 feet

, Page 3 of 162



B) 18 feet


C) 25 feet


D) 50 feet


Answer: B


The NGWA Code of Excellence requires casing to be installed to a minimum depth of 18 feet, or through


unconsolidated material to competent bedrock, to prevent surface water contamination.



Question 2


During a pump service call, the technician finds that the submersible pump runs continuously but


delivers very little water. The pressure gauge shows pressure fluctuating between 20 and 30 psi. What is


the most likely cause?


A) The pressure tank is waterlogged (no air cushion)


B) The check valve is stuck closed


C) The pump motor is overheating


D) The pressure switch is set too high


Answer: A

, Page 4 of 162



A waterlogged pressure tank (bladder failure or lost air charge) causes rapid pressure changes and


short-cycling; the pump runs frequently without holding pressure.



Question 3


A well drilled into a confined aquifer must have the annular space sealed to prevent what?


A) Loss of aquifer pressure only


B) Vertical migration of contaminants from overlying formations into the confined aquifer


C) Corrosion of the casing


D) Entry of sand into the well


Answer: B


Annular space grouting (minimum 10 ft in confined aquifers) seals off the annulus to prevent water and


contaminants from moving vertically between aquifers.



Question 4


An irrigation well produces water that contains hydrogen sulfide (rotten egg odor). Which treatment


method is most effective for removing hydrogen sulfide from well water?


A) Water softener (ion exchange)

Written for

Institution
Exmm
Course
Exmm

Document information

Uploaded on
June 9, 2026
Number of pages
162
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

$34.99
Get access to the full document:

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
STUVIAGRADES Chamberlain College Of Nursing
View profile
Follow You need to be logged in order to follow users or courses
Sold
6482
Member since
4 year
Number of followers
460
Documents
7865
Last sold
1 hour ago
stuvia_US

Welcome To my Store# STUVIA_US My Goal is to help you achieve your desired grades by providing credible study materials I'm happy to help you with quality documents On this page you will find quality study guides,Exams assignments, Research papers and Test Banks all verified correct . you'll find past and recent revised and verified study materials . Stay here and You'll find everything you need to pass !!! . I always ensure my documents are of high standards I am always available to assist 24/7 and answer any queries you may have . Be assured to get good grades and always leave a review after a purchase Refer a friend SUCCESS!!!!

Read more Read less
4.8

1082 reviews

5
976
4
34
3
33
2
14
1
25

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions