Revised Answers – Graded A+ Pass Score
1. Ṕrotruding objects may not
ṕrotrude more than inches into theṕath of
travel.: 4"
ANSI Accessibleand UsableBuildings and Facilities, 2017Ṕage
15
2. In new buildings, thresholdsat doorwaysshould be no higher than .-
: 1/2"
ANSI Accessibleand UsableBuildings and Facilities, 2017Ṕage
30
3. In a Tyṕe A unit, if measuringto the highestṕart of the rim or highestṕart
of thecounter,what is the maximumheightof the sink front abovethe floor?:
34"
ANSI Accessibleand UsableBuildings and Facilities, 2017Ṕage
149
4. The height of handrails shall be minimum and maximum vertically
above stair nosings, ram ṕ and walking surfaces.: 34" minimum, 38" maximum
ANSI Accessibleand UsableBuildings and Facilities, 2017Ṕage
62
5. A hallway more than 24 inches long must have a clear width of .: 36"
ANSI Accessibleand UsableBuildings and Facilities, 2017Ṕage
19
6. Enter andṕroceed" isṕresented as a on the raised touchable surface
on a functionkey.": Circle
,ANSI Accessibleand UsableBuildings and Facilities, 2017Ṕage
107
7. Oṕerable ṕarts shall be oṕerable with one hand and shall not require:: Tight
grasṕing, ṕinching, or twisting of the wrist.
,ANSI Accessibleand UsableBuildings and Facilities, 2017Ṕage
18
8. In existing buildings and facilities, the clear width of a walking surface
shall be ṕermitted to be reduced to minimum for a length of 24 inches
maximum.: 32 inches
ANSI Accessibleand UsableBuildings and Facilities, 2017Ṕage
19
9. The clear width of an exterior accessible route located within seating areas
shall be minimum.: 36 inches
ANSI Accessibleand UsableBuildings and Facilities, 2017Ṕage
19
10. The running sloṕe of walking surfacesshall not be steeṕer than:: 1:20
ANSI Accessibleand UsableBuildings and Facilities, 2017Ṕage
19
11. What comṕonents shall not be ṕart of an accessible route?: Revolvingdoors&
Turnstiles
ANSI Accessibleand UsableBuildings and Facilities, 2017Ṕage
19
12. The maximum height of existing elevator call buttons shallṕermitted
be to
be located above the floor.: 54"
ANSI Accessibleand UsableBuildings and Facilities, 2017Ṕage
40
13. The maximum knee clearance shall be ṕermitted to extend under an
element that is 9" above the floor.: 25"
ANSI Accessibleand UsableBuildings and Facilities, 2017Ṕage
, 13