Code B1Code
Study
Residential
Guide Questions
Building
Code B1 and
Code
Study
Answers
Residential
GuideLatest
Questions
Code
2026_2027
B1
and
Study
Answers
Version.pdf
GuideLatest
Questions
2026_2027
and Answers
Version.pdf
Latest 2026_2027 Version.pdf
Building Code
Residential Code
B1 Study Guide
Questions and
Answers Latest
2026/2027 Version
Building Code ResidentialBuilding
Code B1Code
Study
Residential
Guide Questions
Building
Code B1 and
Code
Study
Answers
Residential
GuideLatest
Questions
Code
2026_2027
B1
and
Study
Answers
Version.pdf
GuideLatest
Questions
2026_2027
and Answers
Version.pdf
Latest 2026_2027 Version.pdf
,Building Code, Residential Code, B1 Study Gudie.pdf Building Code, Residential Code, B1 Study Gudie.pdf Building Code, Residential Code, B1 Study Gudie.pdf
Glazing in fixed and operable panels of swinging, hazardous location (R308.4.1)
sliding and bifold doors shall be considered to be
a______
Glazing in an individual fixed or operable panel 9, 18, 36 (R308.4.3)
requires safety glazing if the pane is larger
than_____square feet with a bottom edge less
than____inches above the floor and a top edge
greater than_____inches above the floor and a walking
surface is within 36 inches of the glazing, measure
horizontally.
Glazing where the bottom exposed edge of the 36 (R308.4.6)
glazing is less than_____inches above the plane of the
adjacent walking surface of stairways, landings
between flights of stairs and ramps shall be safety
glazing.
Glazing adjacent to the landing at the bottom of a 30, 60 (R308.4.7)
stairway where the glazing is less than_____inches
above the landing and within a_____inch horizontal
arc less that 180 degrees from the bottom tread
nosing shall be safety glazing.
Garage floor surfaces shall be of approved ____ Noncombustible (R309.1)
material.
Building Code, Residential Code, B1 Study Gudie.pdf Building Code, Residential Code, B1 Study Gudie.pdf Building Code, Residential Code, B1 Study Gudie.pdf
,Building Code, Residential Code, B1 Study Gudie.pdf Building Code, Residential Code, B1 Study Gudie.pdf Building Code, Residential Code, B1 Study Gudie.pdf
Carports shall be open on not less than_____sides. Two (R309.2)
Basements, habitable attics and every sleeping emergency escape, rescue opening (R310.1)
room shall have not less than one operable ____ ____
and ____ ____.
Emergency escape and rescue openings shall have 44 (R310.2.3)
the bottom of the clear openings not greater
than_____ inches above the floor.
Emergency escape and rescue openings shall have 5.7 (R310.2.1)
a net clear opening of not less than_____square feet.
For emergency escape and rescue openings, the 24, 20 (R310.2.2)
minimum net clear opening height dimension shall
be____ inches. The minimum net clear opening width
dimension shall be _____ inches.
The horizontal area of the area well serving an 9, 36 (R310.4.1)
emergency escape and rescue opening shall not be
less than _____ square feet with a horizontal
projection and width of not less than ____ inches.
Area wells with a vertical depth greater than_____ 44 (R310.4.2)
inches shall be equipped with an approved,
permanently affixed ladder or steps.
Building Code, Residential Code, B1 Study Gudie.pdf Building Code, Residential Code, B1 Study Gudie.pdf Building Code, Residential Code, B1 Study Gudie.pdf
, Building Code, Residential Code, B1 Study Gudie.pdf Building Code, Residential Code, B1 Study Gudie.pdf Building Code, Residential Code, B1 Study Gudie.pdf
Area wells serving emergency escape and rescue drainage (R310.4.3)
openings shall be designed for proper____.
Not less than one egress door shall be provided for 32 (R311.2)
each dwelling unit. The egress door shall be side
hinged, and shall provide a clear width of not less
than_____ inches.
A wall supporting any vertical load in addition to its Load-bearing (R202)
own weight is a _____-_____ wall.
What is the minimum uniformly distributed live load 30 pounds per square foot (R301.5)
for habitable attics and attics served with fixed
stairs?
For townhouse separation, a parapet is not required 4, 4 (R302.2.4)
when the roof sheathing is fire-retardant-treated
wood for a distance of ___ feet on each side of the
wall and there are no penetrations in the roof within
___ feet of the common wall.
Wood structural panels with a thickness of not less 7/16, 8 (R301.2.1.2)
than____ inch and a span of not more than____ feet
shall be permitted for opening protection in wind
borne debris regions.
Building Code, Residential Code, B1 Study Gudie.pdf Building Code, Residential Code, B1 Study Gudie.pdf Building Code, Residential Code, B1 Study Gudie.pdf