Latest Version |Already Graded A+
After what date was the F-24 certificate of Fitness not recognized. ✔Correct Answer-July 31,
2014
How often must this certificate be renewed? ✔Correct Answer-Every 3 years
In what types of buildings and occupancies are coordinators of fire safety and alarm systems in
homeless shelter required? ✔Correct Answer-Homeless shelters, one-way voice
communication systems, or occupied for more tha n fifteen persons for a period of more than
30 days.
What is the certificate of occupancy? ✔Correct Answer-Determines the number of occupants
authorized to be in the shelter.
Alarm Silence Switch ✔Correct Answer-Silences the building's audible and visual devices after
evacuation is complete while the source of the alarm is being investigated.
Building Occupants ✔Correct Answer-All persons in the shelter
Carbon Monoxide Detector ✔Correct Answer-Device that senses carbon monoxide
Central Station Company ✔Correct Answer-Receives alarm signals from a protected premise
and retransmits or otherwise reports such alarm signals to the FDNY
Evacuation ✔Correct Answer-Emptying of a building
Emergency Preparedness Plan ✔Correct Answer-Provide the information, guidance, direction
and assistance needed to protect the safety of building occupants.
Fire Drill ✔Correct Answer-A training exercise
Fire Guard ✔Correct Answer-Fire guards report any fire safety violations to the Coordinator of
Fire Safety and Alarm Systems in Homeless Shelters.
Fire Triangle ✔Correct Answer-A fire requires fuel, oxygen, and heat.
Free Burning Stage of a Fire ✔Correct Answer-Second stage of the three stages of a fire. The
fully developed stage of a fire.
, Incipient Stage of a Fire ✔Correct Answer-First stage of the three stages of a fire. The growth
stage.
In-Building Relocation Area (IBRA) ✔Correct Answer-A designated are in a building to which
building occupants may be relocated
Off-Line ✔Correct Answer-Periods of time when CS will, per request of building owner, not
transmit fire alarm signals.
One-Way Voice Communication ✔Correct Answer-Makes announcements from the lobby to
building occupants in their apartments/rooms.
Out of Service Signage ✔Correct Answer-placard (tag) over a defective device (job of
impairment coordinator)
Partial Evacuation ✔Correct Answer-The emptying of a building of some but no all building
occupants in response to a fire or an emergency
Phase 1 Emergency Elavator Recall ✔Correct Answer-Involves using a keyed switch to bring
the elevators back to the lobby.
Shall ✔Correct Answer-Refers to a requirement of the fire code
Should ✔Correct Answer-Refers to policies, procedures, and practices recommended but not
required.
Smoldering Stage of a Fire ✔Correct Answer-The third stage in the three stages of a fire. Fire
has an unlimited supply of fuel but limited oxygen. Visible flames will have diminished and the
fire will smolder and continue to produce smoke and toxic gases.
Unnecessary Alarm ✔Correct Answer-Response proved unnecessary.
Unwarranted Alarm ✔Correct Answer-Result of improper installation, improper maintenance,
malfunction, or other factor.
How many people were estimated to have spent the night in a NYC homeles shelter in 2013.
How many were children? ✔Correct Answer-45,000. 19,000 children.
It is imperative that Coordinators or Fire Safety and Alarms Systems in Homeless Shelters
ensure: ✔Correct Answer-immediate correction of any fire safety violations and familiarity
with emergency preparedness plan
Fire summary of homelss shelter in Paris, Texas ✔Correct Answer-When: 2009
42 bed shelter