To determine the proper test pressure that should be used to test a system leaks ,
the system component data plates should be referenced and - ANSWER-the lowest
of all the listed pressure should be used .
An ultrasonic leak detector , microfoam solution , or a trace gas , and an electronic
detector can all be used to - ANSWER-locate a small leak
When working with pressurized nitrogen , the tank should always be equipped with
a ; - ANSWER-pressure regulator .
A system that passes a leak test should be ; - ANSWER-evacuated prior to being
charged .
When brazing or soldering , it is always a good safety practice to have ; -
ANSWER-the proper fire extinguisher near the work area
, When soldering , what is used to prevent oxides from forming and help the molten
solder to flow more easily into the joint ? - ANSWER-B. Chemical flux
The tank used for oxygen in portable oxyacetylene kits is typically a ( n -
ANSWER-" R " tank ( 20 cubic feet ) .
The tank used for an air - acetylene torch is typically a ( n ) ; - ANSWER-A. " B "
tank ( 40 cubic feet )
greater than a 1 : 1 ratio of oxygen to acetylene , is called ; When brazing with
oxyacetylene , a flame that has slightly more oxygen than acetylene , ' - ANSWER-
D. an oxidizing flame .
greater than a 1 : 1 ratio of acetylene to oxygen , is called When brazing with
oxyacetylene , a flame that has slightly more acetylene than oxygen , - ANSWER-a
carburizing flame
When brazing with oxyacetylene , a flame that has a 1 : 1 ratio of oxygen to
acetylene , is called ; - ANSWER-C. a neutral flame .
On a nitrogen tank regulator , the gauge on the left side displays the ; - ANSWER-
C. outlet pressure
On a nitrogen tank regulator , the gauge on the right side displays the ; -
ANSWER-D. tank pressure .