Existing Work A plumbing system or any part thereof installed prior to March 11, 2005.


Soil Pipe Any pipe that conveys the discharge of toilets, urinals or fixtures having similar
functions to the building drain or building sewer. The discharge may be conveyed
with or without the discharge from other fixtures


Water Distribution Pipe A pipe within the building or on the premises that conveys water from the water
service pipe to the point of usage


Barometric Loop. A vertical loop of pipe, rising to a height sufficient to prevent back-siphonage
from occurring in the potable water supply pipe. (Approximately 35 feet,
depending on the weight of the atmosphere.)


Developed Length The length of a pipeline as measured along the center line of the pipe or fittings.


Roughing-in. The installation of all parts of the plumbing system that can be completed prior to
the installation of fixtures. This includes drainage piping, water supply piping, vent
piping, the necessary fixture supports, and any fixtures that are built into the
building.


Trap Seal The vertical distance between the crown weir and the top of the dip of the trap.


Air Gap (Drainage System). The unobstructed vertical distance through the free atmosphere between the
outlet of a waste pipe and the flood level rim of the receptacle into which the
waste discharges.
Air

, Fixture Unit. A unit of liquid flow used in sizing both supply and drainage pipes. It is equal to 1
cubic foot per minute or approximately 7.5 gallons per minute.


Liquid Waste Discharge from any fixture, appliance, area or appurtenance that does not contain
human or animal waste matter suspended in a solution.


Vacuum Any pressure less than that exerted by the atmosphere


Branch Interval A distance along a soil or waste stack corresponding in general to a story height,
but not less than eight feet in vertical height, and wherein the horizontal branches
from one floor or story of a building are connected to the stack


Testing water supply shall be at a pressure no less than? 125 PSI


Storm or Sanitary drains shall be installed at a slope that: a slope that produces a computed velocity of discharge of not less than two feet
per second.


Horizontal drainage piping which is (3) three inches in ¼ inch per foot
diameter or smaller shall be installed with a minimum
uniform pitch


Horizontal drainage piping which is larger than three 1/8 inch per foot
inches in diameter shall be installed with a minimum
uniform pitch of


Whenever there is reason to believe that the plumbing test and/or inspection, and any defects found shall be corrected as required in
system of any building has become defective, it shall be writing by the Inspector
subjected


Waste and Vent shall be tested for? until there is a uniform gauge pressure of five P.S.I.G. or sufficient pressure to
balance a column of mercury ten inches in height. This pressure shall be held
without introduction of additional air for a period of at least 15 minutes. The gauge
used for this test shall be calibrated in increments no greater than 1/10 of a pound.
c


Upon completion of a section or of the entire water 125 pounds per square inch
supply system when roughed, it shall be tested and
proved tight under a pressure not less than


Upon notice of a request for an Inspection of the rough two working days after receipt of such notice
plumbing, the Inspector shall make the Inspection within


Four acceptable tests for Drain and Waste Peppermint Test , Air Test, Water Test, Smoke Test


Quarter bends, or their equivalent may be used in soil horizontal to the vertical.
and waste lines when the change in the direction of the
flow is from the


Short sweep fittings may be used in a branch waste line one outlet and cleanouts are provided.
when the waste line serves only

Document information

Uploaded on
June 2, 2026
Number of pages
8
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$15.69

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Briwisescore
3.0
(1)
Sold
22
Followers
5
Items
11440
Last sold
4 days ago


Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions