Written by students who passed Immediately available after payment Read online or as PDF Wrong document? Swap it for free 4.6 TrustPilot
logo-home
Document preview thumbnail
Preview 2 out of 14 pages
Exam (elaborations)

NYC Electrician Exam Questions & Answers With Correct Answers

Document preview thumbnail
Preview 2 out of 14 pages

NYC Electrician Exam Questions & Answers With Correct Answers /. The value of current, time, or both at which an adjustable circuit breaker is set to trip is known as? A) Inverse time B) Ampacity C) Automatic D) Setting - Answer-D) Setting. Art. 100 Defintions /.The cross-sectional area of three or more THW conductors in a conduit must not exceed what percent of the cross-sectional area of the conduit? A) 30% B) 40% C) 50% D) 60% - Answer-B) 40 % Chapter 9 Table 1 /.EMT must be supported within what distance from an outlet box, junction box, device box, cabinet, conduit body or other terminations? A) 3 feet B) 4 feet C) 5 feet D) 6 feet - Answer-A) 3 feet Article 358.30 (A) /.When a branch circuit feeds both noncontinuous and continuous loads, the circuit must be sized to accommodate 100% of the noncontinuous load plus what percent of the continuous load? A) 110% B) 115% C) 120 % D) 125% - Answer-D) 125% Article. 210.20 (A) /.What is the allowable Ampacity of a 600 MCM copper conductor type TW? A) 300 Amps B) 350 Amps C) 355 Amps D) 400 Amps - Answer-B) 350 Amps Table- 310.16 /.The name given to a system or circuit conductor that is intentionally grounded is? A) Grounding Conductor B) Bonding Conductor C) High-leg conductor D) Grounded or neutral conductor - Answer-D) Grounded or Neutral Conductor Article 100 Definitions /.The panels of switchboards must be made of? A) Moisture resistant, noncombustible material B) Raintight material C) Impact-resistant material D) Waterproof material - Answer-A) Moisture-resistant, noncombustible material Article 408.50 /.A metal pole supporting a light fixture shall have an accessible handhole not less than ________ inches? A) 2 X 6 inches B) 3 X 4 inches C) 2 X 4 inches D) 4 X 8 inches - Answer-C) 2 X 4 inches Article 410.30 (B) (1) /.The largest standard rating for fuses and inverse time circuit breakers is? A) 1000 amps B) 1600 amps C) 1200 amps

Content preview

NYC Electrician Exam Questions &
Answers With Correct Answers

/. The value of current, time, or both at which an adjustable circuit breaker is set to trip is
known as?

A) Inverse time
B) Ampacity
C) Automatic
D) Setting - Answer-✅D) Setting.

Art. 100 Defintions

/.The cross-sectional area of three or more THW conductors in a conduit must not
exceed what percent of the cross-sectional area of the conduit?

A) 30%
B) 40%
C) 50%
D) 60% - Answer-✅B) 40 %

Chapter 9 Table 1

/.EMT must be supported within what distance from an outlet box, junction box, device
box, cabinet, conduit body or other terminations?

A) 3 feet
B) 4 feet
C) 5 feet
D) 6 feet - Answer-✅A) 3 feet

Article 358.30 (A)

/.When a branch circuit feeds both noncontinuous and continuous loads, the circuit must
be sized to accommodate 100% of the noncontinuous load plus what percent of the
continuous load?

A) 110%
B) 115%
C) 120 %
D) 125% - Answer-✅D) 125%

, Article. 210.20 (A)

/.What is the allowable Ampacity of a 600 MCM copper conductor type TW?

A) 300 Amps
B) 350 Amps
C) 355 Amps
D) 400 Amps - Answer-✅B) 350 Amps


Table- 310.16

/.The name given to a system or circuit conductor that is intentionally grounded is?

A) Grounding Conductor
B) Bonding Conductor
C) High-leg conductor
D) Grounded or neutral conductor - Answer-✅D) Grounded or Neutral Conductor

Article 100 Definitions

/.The panels of switchboards must be made of?

A) Moisture resistant, noncombustible material
B) Raintight material
C) Impact-resistant material
D) Waterproof material - Answer-✅A) Moisture-resistant, noncombustible material

Article 408.50

/.A metal pole supporting a light fixture shall have an accessible handhole not less than
________ inches?

A) 2 X 6 inches
B) 3 X 4 inches
C) 2 X 4 inches
D) 4 X 8 inches - Answer-✅C) 2 X 4 inches

Article 410.30 (B) (1)

/.The largest standard rating for fuses and inverse time circuit breakers is?

A) 1000 amps
B) 1600 amps
C) 1200 amps

Document information

Uploaded on
May 27, 2026
Number of pages
14
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$17.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Brainariam
3.3
(27)
Sold
156
Followers
7
Items
8389
Last sold
1 day ago


Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions