VERIFIED ANSWERS COMPREHENSIVE REVIEW
◉ According to the Specifications for Structural Steel Buildings,
which of the following steel members are allowed to be unidentified
steel?
Answer: Unimportant members, where their physical properties and
weldability would not affect the structure strength - Section A31b,
Specifications for Structural Steel Buildings
◉ According to the Code of Standard Practice for Steel Buildings and
Bridges, how is steel of special material to be identified?
Answer: It is marked by the supplier - Section 5.1.1, Code of
Standard Practice for Steel Buildings and Bridges
◉ According to the Code of Standard Practice for Steel Buildings and
Bridges, how are fabricators stock steel material identified?
Answer: Certified mill test reports - Section 5.2.2 - Code of Standard
Practice for Steel Buildings and Bridges
◉ According to the Specification for Structural Steel Buildings, what
ASTM Standard would apply to a sample for structural steel pipe?
Answer: A53 - Section A31a - Specification for Structural Steel
Buildings
,◉ According to the Code of Standard Practice for Steel Buildings and
Bridges, the number of samples required to be tested for structural
steel is:
Answer: The number specified by the ASTM specification - Section
5.1.1 - Code of Standard Practice for Steel Buildings and Bridges
◉ According to the Specification for Structural Steel Buildings,
which ASTM standard would apply to a sample for structural steel
plates?
Answer: A36, A283, and A242 - Section A31a - Specification for
Structural Steel Buildings
◉ According to the Specification for Structural Steel Buildings,
"blank" tests are required for samples for built-up sections
consisting of plates over 2 inches in thickness.
Answer: Charpy V-notch testing - Section A31d, Specification for
Structural Steel Buildings
◉ According to the Specification for Structural Steel Buildings, ASTM
standard "blank" would apply to a sample for structural steel bars.
Answer: A36, A529, and A572 - Specification for Structural Steel
Buildings
, ◉ Steel furnished for structural load-carrying purposes shall be
properly :
Answer: Identified - 2009 IBC, Section 2203.1
◉ Steel that is not readily identifiable as to grade by marking and
test records shall be:
Answer: tested - 2009 IBC, Section 2203.1
◉ Where materials or assemblies are required by this code to be
labeled, such material and assemblies shall be labeled by:
Answer: An approved agency - 2009 IBC, Section 1703.5
◉ Inspection of the steel frame for compliance with the approved
construction documents should verify:
Answer: Member location, Bracing, and Stiffening - 2009 IBC,
Section 1704.3.2.
◉ Continuous inspection of bolt pre-tensioning is required when
using:
Answer: The calibrated wrench method - 2009 IBC, Section
1704.3.3.3.
◉ Where required by the code, the building owner shall employ a
registered design professional to perform: