• A bean is defined as a structural or non structural solid member which could
jacks down into the rooms base more than _____ and is located more than _____
apart on center. CORRECT ANSWER: Down more than4" and 3' apart
• The following are examples of line type detection except. CORRECT ANSWER:
ionization smoke detector
• He could tonight a circuit to which automatic or manual initiating devices are
connected where the signal received does not identify the device operated is
called?. CORRECT ANSWER: A signaling line circuit
• Secondary power supplies are required to have sufficient power to operate the fire
alarm system in a non alarm condition for _______ hours and then be capable of
operating all notification devices for a minimum of ______ minutes. CORRECT
ANSWER: 24 hours and 5 minutes
• Secondary power supplies for emergency voice evacuation systems are required
to have sufficient power to operate the system in a non along condition for ______
hours and kin be capable of operating the system during a fire or other emergency
for a minimum of ______ minutes. CORRECT ANSWER: 24 hours and 15
minutes under maximum load
• Secondary power supply shall automatically provide power to the protected
premises fire alarm system within _______ seconds when ever primary power fails
to provide minimum voltage required for proper operation?. CORRECT
ANSWER: 10 seconds
• Cording to NFPA chapter 4, batteries shall be permanently marked with what
information?. CORRECT ANSWER: Month and year of manufacture
• NFPA 72 "record of completion" is prepared:. CORRECT ANSWER: upon
completion of installation at just acceptance test
, • According to NFPA chapter 4, the control panel charging apparatus shall be taken
full of recharging batteries within _____ _____ after batteries have been fully
discharged?. CORRECT ANSWER: 24 hours
• According to the fire code of New York City, smoke detectors may be tested by
the following methods except for:. CORRECT ANSWER: Measured aerosol
smoke introduced into the detector
• What type of drawing typically shows correct conductor counts?. CORRECT
ANSWER: Riser diagrams
• According to the fire code and fire rules, who is responsible for preventing
unnecessary and unwanted alarms?. CORRECT ANSWER: Owner of a promise or
a part thereof
• I'll take you way and which according to NFPA chapter 4, a coded alarm signal
shall consist of not less than ______ complete rounds of the number transmitted.
Each round shall consist of not less than a ______ impulses. CORRECT
ANSWER: 3 rounds and 3 impulses
• According to the fire rules, who is responsible for making in trees in the smoke
detector maintenance log?. CORRECT ANSWER: The fire safety director or a
person designated by building owners if no FSD
• According to NFPA chapter 4, installation Conductors shall be monitored for
integrity. The occurrence of a single open or single ground fault condition shall be
automatically indicated within ______ seconds. CORRECT ANSWER: 200
seconds
• All of the following are good conductors of electricity except. CORRECT
ANSWER: carbon
• Which of the following is an example of an initiating device?. CORRECT
ANSWER: Supervisory air pressure switch and photo electric smoke detector
• Into voice along and initiating device which is destroyed as a result of its
operation is what type?. CORRECT ANSWER: Non restorable