Written by students who passed Immediately available after payment Read online or as PDF Wrong document? Swap it for free 4.6 TrustPilot
logo-home
Exam (elaborations)

ACI CONCRETE FIELD TESTING TECHNICIAN GRADE 1 PRACTICE TEST EXAM

Rating
-
Sold
-
Pages
40
Grade
A+
Uploaded on
14-05-2026
Written in
2025/2026

What must be done to the concrete surrounding the temperature measuring device after the device is submerged in the fresh concrete. - answer-Gently press the concrete around the temperature measuring device at the surface of the concrete The sensor of the temperature measuring device shall be submerged a minimum of _____ in. [_____mm] into the freshly mixed concrete. - answer-3 in. [75 mm] The temperature measuring device shall have a capacity of measuring temperature of freshly mixed concrete to +- _____ degrees F [+- _____ C] throughout a range of _____. - answer-1 degree F [0.5 C], 30 degrees F to 120 F [0 C to 50 C] The temperature measuring device shall be calibrated _____, or whenever there is a question of _____. - answer-Annually, accuracy The temperature of concrete may be measured in a wheelbarrow. True or False? - answer-True The temperature of concrete may be measured in a wall form. True of False - answer-True

Show more Read less
Institution
ACI CONCRETE FIELD TESTING TECHNICIAN GRADE 1
Course
ACI CONCRETE FIELD TESTING TECHNICIAN GRADE 1

Content preview

ACI CONCRETE FIELD TESTING
TECHNICIAN GRADE 1 PRACTICE
TEST EXAM

What must be done to the concrete
surrounding the temperature measuring
device after the device is submerged in the
fresh concrete. - answer-Gently press the
concrete around the temperature
measuring device at the surface of the
concrete


The sensor of the temperature measuring
device shall be submerged a minimum of
_____ in. [_____mm] into the freshly mixed
concrete. - answer-3 in. [75 mm]

,The temperature measuring device shall
have a capacity of measuring temperature
of freshly mixed concrete to +- _____
degrees F [+- _____ C] throughout a range
of _____. - answer-1 degree F [0.5 C], 30
degrees F to 120 F [0 C to 50 C]


The temperature measuring device shall be
calibrated _____, or whenever there is a
question of _____. - answer-Annually,
accuracy


The temperature of concrete may be
measured in a wheelbarrow. True or False?
- answer-True


The temperature of concrete may be
measured in a wall form. True of False -
answer-True

,A composite sample of concrete is
required even if the only purpose for
obtaining the sample is to determine
temperature. True of False? - answer-
False


What must be done to the sample container
prior to sampling the concrete? - answer-
Dampen (with water)


How long must the temperature measuring
device remain in the freshly mixed
concrete? - answer-At least 2 minutes but
not more than 5 minutes


After the temperature of the concrete is
read, what is required? - answer-Reporting
of temperature

, The temperature of concrete is reported to
the nearest _____ degrees F [_____ C] -
answer-1 degree F [0.5 C]


According to ASTM C1064, what is one
reason to take the temperature of
concrete? - answer-Verify conformance to
a specified requirement for temperature of
concrete


A maximum temperature of freshly mixed
concrete is specified in ASTM C1064. True
of False? - answer-False


The sample of concrete used for
temperature determination must be rodded
25 times. True or False? - answer-False

Written for

Institution
ACI CONCRETE FIELD TESTING TECHNICIAN GRADE 1
Course
ACI CONCRETE FIELD TESTING TECHNICIAN GRADE 1

Document information

Uploaded on
May 14, 2026
Number of pages
40
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

$19.49
Get access to the full document:

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
docciel NURSING
View profile
Follow You need to be logged in order to follow users or courses
Sold
25
Member since
3 year
Number of followers
11
Documents
1207
Last sold
1 day ago

5.0

3 reviews

5
3
4
0
3
0
2
0
1
0

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions