NICET - Fire Alarm Systems (Level 2)
Exam Questions & Answers (Grade
A+)
The International Mechanical Code requires a duct smoke detector
in the return for units over ________ cfm -
correct answer ✅2000 cfm


The International Mechanical Code (IMC) requires a duct smoke
detector in the supply for units over __________ cfm -
correct answer ✅15000


Digital alarm communicator transmitters (DACT) which use call
forwarding to the DACR shall be tested with what frequency? -
correct answer ✅4 hours


NPLFA cables shall be insulated to __________ v -
correct answer ✅600v


PLFA cables shall be insulated to _______ v -
correct answer ✅300v


For sprinkler systems what type of signal is a fire pump running?
a. alarm

,NICET - Fire Alarm Systems (Level 2)
Exam Questions & Answers (Grade
A+)
b. supervisory
c. trouble
d. A and B -
correct answer ✅d


A positive alarm sequence requires the approval of the
___________. -
correct answer ✅AHJ


How often shall a remote annunciator used at the main entrance of
a low-rise residential apartment building be inspected? -
correct answer ✅Semniannually


According to NFPA 72, the off-normal signal of a tamper switch
control valve used in sprinkler piping that is required for pressure-
actuated water flow alarm switch, shall not be restored at any valve
position except _____________? -
correct answer ✅Normal


When installing a heat-sensing fire detector on the bottom of a
beam, the beam must be less than _____________ inches in depth

,NICET - Fire Alarm Systems (Level 2)
Exam Questions & Answers (Grade
A+)
and _____________ feet on center? -
correct answer ✅12 in; 8 ft


Where a door is released to provide a 2-hour fire rating directly
from the smoke detector, the detector shall be ______________
a. mounted as close as possible to the door being released
b. listed for door releasing service
c. identified for door releasing service
d. of the photoelectric type only -
correct answer ✅b


According to NFPA, smoke detectors installed in the ducts of HVAC
systems shall initiate:
a. alarm
b. supervisory
c. trouble
d. a or b -
correct answer ✅d


According to the IBC, shop drawings shall include:

, NICET - Fire Alarm Systems (Level 2)
Exam Questions & Answers (Grade
A+)
a. floor plan that indicates the use of all rooms
b. annunciators
c. voltage drop calculations
d. all of the above -
correct answer ✅d


The location of remotely located power supplies shall be identified
at the ________________ -
correct answer ✅Master Control Unit


Heat detectors will be installed in an elevator hoistway to shut
down power to the elevator prior to sprinkler activation. The heat
detectors need to have a _______________ temp rating and shall
be located ______________ in from the sprinkler head. -
correct answer ✅lower; 24 in


A local community college is what type of occupancy classification?
-
correct answer ✅Group B

Document information

Uploaded on
April 22, 2026
Number of pages
114
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$15.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Cindellera
3.9
(31)
Sold
183
Followers
3
Items
15435
Last sold
5 days ago


Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions