1. A residential drainage pipe is required to have a minimum slope
of:
A. 1/16 inch per foot
B. 1/8 inch per foot
C. 1/4 inch per foot
D. 1/2 inch per foot
Answer: C
Rationale: Drainage piping in residential systems is typically
required to slope at 1/4 inch per foot to ensure proper gravity
flow and prevent solids buildup.
2. The primary purpose of a plumbing trap is to:
A. Increase water pressure
B. Prevent sewer gases from entering the building
C. Improve drainage velocity
D. Filter solid waste
Answer: B
Rationale: A trap maintains a water seal that blocks sewer gases
from entering occupied spaces.
3. The minimum water supply pressure required at fixture outlets is
generally:
A. 5 psi
, B. 10 psi
C. 15 psi
D. 20 psi
Answer: C
Rationale: Most plumbing codes require at least 15 psi at fixture
outlets for proper operation.
4. Which pipe material is commonly approved for DWV systems in
residential construction?
A. Lead
B. PVC
C. Galvanized steel
D. Cast iron only
Answer: B
Rationale: PVC is widely approved for drainage, waste, and vent
systems due to corrosion resistance and ease of installation.
5. A backflow preventer is installed to:
A. Increase water flow
B. Prevent contamination of potable water
C. Reduce pipe noise
D. Increase pipe pressure
Answer: B
Rationale: Backflow preventers stop contaminated water from
reversing into potable water systems.
6. The vent system in plumbing primarily serves to:
A. Increase water pressure
B. Allow sewer gases into the building
C. Maintain atmospheric pressure in the drainage system
D. Increase drainage speed
Answer: C
, Rationale: Vent systems equalize pressure in drainage piping to
ensure smooth flow and trap protection.
7. The maximum distance a trap may be installed from a vent is
governed by:
A. Pipe color
B. Pipe diameter
C. Code fixture unit tables
D. Water pressure
Answer: C
Rationale: Plumbing codes specify maximum trap-to-vent
distances based on fixture units and pipe size.
8. A water heater temperature relief valve is required to:
A. Increase water temperature
B. Prevent over-pressurization
C. Control water flow rate
D. Reduce scaling
Answer: B
Rationale: The T&P valve releases water if temperature or
pressure exceeds safe limits.
9. Which fitting is used to change direction in a DWV system with
minimal restriction?
A. 90-degree elbow
B. Sanitary tee
C. Wye fitting
D. Cross fitting
Answer: C
Rationale: A wye fitting allows smoother directional change and
better flow characteristics in drainage systems.