Written by students who passed Immediately available after payment Read online or as PDF Wrong document? Swap it for free 4.6 TrustPilot
logo-home
Document preview thumbnail
Preview 2 out of 7 pages
Exam (elaborations)

MRI ARMRIT Exam Questions Version 1/MRI ARMRIT prep Exam Questions and Answers Practice Questions with Solutions Newest | Already Graded A+

Document preview thumbnail
Preview 2 out of 7 pages

MRI ARMRIT Exam Questions Version 1/MRI ARMRIT prep Exam Questions and Answers Practice Questions with Solutions Newest | Already Graded A+

Content preview

ARMRIT Practice Exam
Study online at https://quizlet.com/_flkxoa

1. The T2 process is also known as:: Spin-Spin
2. The tissue characteristic that provides more tissue contrast and pathological
information is:: T2 effects
3. The basic process of MR signal generation contains two basic steps, they
are:: Stimulation & Relaxation
4. Which statement is true of the relaxation process?: Without the effects of T2* (star), T2
decay continues
5. Which type of MRI magnet requires cryogen to cool magnetic coils to 4
degrees Kelvin?: Superconductive
6. Tissues that are very efficient at spin-lattice interactions near the Larmor
frequency, such as fatty tissues, should have: Low T1 values and produces hyperintense signals
7. Which type of electromagnetic coils are employed as a transmitter, receiver
or both?: Radio-frequency coils
8. The process of relaxation begins when:: B1 is turned off
9. To symbolize the flow and area of a magnetic field, lines are used which are
called:: Field or flux
10. Which molecule precesses closer to the Larmor frequency?: Fat
11. Which cryogenic material can produce temperature as low as 4 degrees
Kelvin?: Liquid helium
12. Magnetism can be defined as the ability of certain substances to attract:: Iron
Cobalt
Nickel
13. In a large main magnetic field such as those employed in MRI, the motion
of a hydrogen proton has been described as wobbling like a spinning top. This
motion is called:: Precession
14. In comparison to Computed Axial Tomography, a disadvantage of MRI is:: -
Special and costly site planning & shielding
15. The tissue characteristic which depends more on the state (solid, liquid, gas)
of a tissue than any other factor is:: T2 effects
16. The T1 process is also known as:: Spin-Lattice
17. To describe the uniformity of the MRI system's main magnetic field, the term
employed is:: Homogeneity
1/7

, ARMRIT Practice Exam
Study online at https://quizlet.com/_flkxoa

18. The main magnetic field of MRI systems in clinical use must meet an accept-
able specification of:: 20-30 PPM

PPM: parts-per-million
19. A 90 degree radio-frequency pulse will alter the net magnetization vector.
Another effect is:: The hydrogen protons will have phase coherence
20. Which type of electromagnetic coils produce smaller magnetic fields which
allow spatial localization to be performed?: Gradient coils
21. The mechanism of T2 contrast enhancement agents is to:: Decrease T2 relaxation
time, therefore producing low signal
22. MRI systems require rooms that provide specific shielding requirements.
These rooms are lined with what type of materials?: Copper or galvanized steel
23. when is the net magnetization vector at its maximum magnitude?: At equilibrium
24. The tissue characteristic that depends heavily on the relative content of fat
molecules and free water is:: T1 effects
25. In the USA, the MRI system's main magnetic field and the vector that repre-
sents it is symbolized:: Bo
26. After a 90 degree radio-frequency pulse, the net magnetization vector be-
gins to return to equilibrium. When the NMV is half-way between transverse
and equilibrium, what are the magnitudes of the longitudinal component and
the transverse component?: Longitudinal component = greater than zero
Transverse component = greater than zero
27. Which type of electromagnetic coils can be found both inside and outside of
the housing of the MRI magnet?: Radio-frequency coils (body coils & main coil)
28. During the relaxation process, the MR signal grows weaker. The single loss
is known as:: Free Induction Decay

The FID is a damped oscillation at the resonance frequency recorded when the net magnetization is
tipped into the transverse plane

FID is elicited by a single RF pulse (e.g., 90 degrees). The FID decays with the time constant T2*. The decay of the NMR
signal can be recovered by applying a second RF pulse, a 180-degree pulse
2/7

Document information

Uploaded on
April 7, 2026
Number of pages
7
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$14.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
PROLEARNER2
3.0
(2)
Sold
19
Followers
0
Items
1011
Last sold
2 months ago


Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions