COMPLETE STUDY GUIDE
QUESTIONS WITH 100% VERIFIED
ANSWERS (LATEST UPDATE 2026 |
This is Sterile Processing Final Exam, typically the Certified Registered Central Service
Technician (CRCST) exam, is a 3-hour computer-based test consisting of 150 multiple-
choice questions. Of these, 125 are scored and 25 are unscored "pre-test" questions used
for statistical evaluation. To pass, candidates generally need a minimum score of 70%.
Core Exam Domains
The exam is designed to verify a technician's competence in several key areas. The bulk of
the content (over 60%) focuses on cleaning, decontamination, and sterilization processes.
Cleaning, Decontamination & Disinfection (approx. 21%): Focuses on removing
bioburden, preventing soil from drying on instruments, and the use of chemical disinfectants.
Preparation & Packaging (approx. 20%): Covers instrument inspection for cleanliness and
functionality, lubrication (based on Instructions for Use or IFU), and assembly using count
sheets.
Sterilization Process (approx. 26%): Includes knowledge of steam sterilization (the most
common method), low-temperature sterilization, and the use of chemical indicators or
integrators.
Patient Care Equipment & Safety (approx. 10%): Handling of medical equipment and
understanding basic anatomy, physiology, and medical terminology.
Sterile Storage & Inventory Management (approx. 11%): Maintaining the integrity of sterile
items and managing supply distribution.
1
, Documentation & Quality Assurance (approx. 12%): Record maintenance, regulatory
compliance, and testing tools like insulation testers.
Key Study Topics
Bioburden: The number of microorganisms on a contaminated object; pre-cleaning at the
point of use is critical to prevent it from drying.
Moisture Saturation: Crucial for microbial cell wall collapse during heat transfer in
sterilization.
Packaging Methods: Differences between peel packs, wraps, and rigid containers, as well as
wrapping techniques like the envelope or square fold.
Instrument Care: Identification of damaged tools (dull or misaligned) and proper placement
to facilitate sterilization.
Preparation Tips
Resource Manual: The HSPA 9th edition manual is considered the primary source for exam
content.
Eligibility: Full certification requires 400 hours of hands-on experience, verified by a
supervisor.
Study Strategy: Focus heavily on Chapters 7–9, 12–15, 17, 18, and 22 of the manual, which
cover the most heavily weighted sections of the test.
Quiz_________________?
- 64-75 degrees F
- 75% -
ANSWER✅
Sterile Storage standards, temperatures should be at ______ and relative humidity should
be less than ____.
2
, Quiz_________________?
-_____ _______
-_____ _______
-_____ Neutral
-_____ _______
-_____ _______ -
ANSWER✅
Please fill in the blanks on the pH table.
Quiz_________________?
-12x12x20
-12 lbs
-7.2 lbs -
ANSWER✅
Linen packaging material is limited to a size of _______,not weigh more than _______, and
maximum density must not exceed ______.
Quiz_________________?
-14.7^15 psi -
ANSWER✅
What is the Atmospheric room pressure at sea level ?
Quiz_________________?
-2 inches
-8-10 inches -
3
, ANSWER✅
Sterile storage standards, sterile items should be stored at least ___ away from exterior
walls, ______ above the floor and from the ceiling.
Quiz_________________?
-250 and 270-275 degrees F -
ANSWER✅
What are the common temperatures for Steam sterilization ?
Quiz_________________?
-27 psi -
ANSWER✅
At 270 degrees, pressure should be at least ______.
Quiz_________________?
-510k application is used when there are changes in the product.
-Pre-market approval is done when there is a new product being released. -
ANSWER✅
What is a 510k application vs Pre-market approval ?
Quiz_________________?
-64-72 degrees F
-35-70%
-2 Hours -
ANSWER✅
4