1. A technologist is preparing a patient for an IV contrast injection. The patient reports a previous
severe allergic reaction to shellfish. What is the most appropriate action?
A. Proceed with the exam, as shellfish allergy is not a true contraindication for iodinated contrast.
B. Immediately inform the supervising radiologist or ordering physician.
C. Reassure the patient that the reaction was likely not related to contrast media.
D. Administer diphenhydramine (Benadryl) without consulting the physician.
Correct Answer : B
Rationale: A history of severe allergic reaction to shellfish or iodine is a potential indicator of a higher
risk for a reaction to iodinated contrast media. The technologist's primary duty is to advocate for patient
safety. The most appropriate and safest action is to immediately inform the supervising radiologist or
ordering physician so they can evaluate the risk/benefit and order premedication if necessary.
Proceeding without consultation could put the patient at risk. Administering medications is outside the
scope of practice for a radiologic technologist. (Domain: Patient Care)
2. When using an automatic injector for a power injection of IV contrast, what is the most critical
safety check?
A. Ensuring the patient's arm is fully extended.
B. Using a large-bore, short IV catheter.
C. Verifying the venous access is secure, free of infiltration, and the line is patent with a saline flush.
D. Placing the patient in a supine position for the entire procedure.
Correct Answer : C
Rationale: The most critical safety check before a power injection is to ensure the IV line is properly
placed and free of any obstruction or infiltration. A power injector delivers contrast at high pressure; if
the line is not patent or is infiltrated, it can cause severe tissue damage, extravasation, and
compartment syndrome. Verifying patency with a saline flush is the key step to confirm the line is safely
in the vein. (Domain: Patient Care)
,2
3. According to the ARRT Code of Ethics, a radiologic technologist may be in violation for which of the
following?
A. Refusing to perform an exam due to unsafe working conditions.
B. Disclosing a patient's clinical history to a consulting physician.
C. Discussing a patient's diagnosis with a family member without patient consent.
D. Continuing to practice while adhering to ongoing professional development requirements.
Correct Answer : C
Rationale: The ARRT Code of Ethics and HIPAA mandate patient confidentiality. Disclosing protected
health information, such as a patient's diagnosis, to a family member without the patient's explicit
consent is a violation of this duty. (Domain: Patient Care)
Safety
4. Which of the following is the primary function of a grid in radiography?
A. To increase the intensity of the x-ray beam.
B. To reduce the amount of scatter radiation reaching the image receptor.
C. To increase the exposure latitude of the image receptor.
D. To reduce the overall exposure to the patient.
Correct Answer : B
Rationale: The primary purpose of an x-ray grid is to improve image contrast by absorbing scatter
radiation that is produced when the primary x-ray beam interacts with the patient's tissues. By reducing
scatter, the grid increases image contrast and clarity. (Domain: Safety)
5. To minimize radiation exposure to the patient, which of the following should be used?
A. The largest focal spot size available.
B. The lowest possible milliamperage (mA) to shorten exam time.
C. The highest possible kilovoltage peak (kVp) and the lowest acceptable milliamperage (mA) to achieve
a quality image.
D. A grid for all examinations, regardless of the body part.
Correct Answer : C
Rationale: Using a higher kVp increases the penetrability of the beam, allowing the use of a lower mAs,
which directly reduces the radiation dose to the patient. The principle is to use the "highest kVp and
lowest mAs" that still produces a diagnostic image, in accordance with the ALARA (As Low As Reasonably
Achievable) principle. (Domain: Safety)
6. A technologist is performing a portable chest x-ray in a busy ICU. Which of the following is the best
way to minimize the dose to other patients and staff?
A. Use a lower kVp to reduce the beam's energy.
B. Use the lowest possible mAs that still produces a diagnostic image.
C. Maximize the distance between the patient and the x-ray tube.
D. Use a grid for all portable chest examinations.
Correct Answer : B
Rationale: The cardinal principle of radiation protection for controlling exposure is to keep the dose "As
Low As Reasonably Achievable" (ALARA). Using the lowest possible mAs (tube current exposure time
,3
product) directly reduces the number of x-rays produced, thereby lowering the radiation dose to both
the patient and anyone in the vicinity. (Domain: Safety)
Image Production
7. What is the effect of using a higher kilovoltage peak (kVp) on the x-ray beam?
A. Decreased beam intensity and lower patient dose.
B. Increased beam intensity and longer wavelength.
C. Increased beam penetrability and lower patient dose.
D. Decreased beam penetrability and higher patient dose.
Correct Answer : C
Rationale: Increasing the kVp increases the average energy of the x-ray photons, making the beam more
penetrating (higher quality). This allows the technologist to use a lower mAs, which reduces the total
number of x-ray photons and therefore the patient's radiation dose. (Domain: Image Production)
8. Which of the following is the most common type of x-ray interaction that contributes to the
formation of the radiographic image?
A. Photoelectric absorption.
B. Compton scattering.
C. Coherent scattering.
D. Pair production.
Correct Answer : A
Rationale: The photoelectric effect is the primary interaction responsible for producing diagnostic image
contrast. In this process, an x-ray photon is completely absorbed by an inner-shell electron of an atom in
the patient's tissue. This differential absorption based on tissue density and atomic number creates the
visible contrast on the radiographic image. (Domain: Image Production)
9. What is the purpose of automatic exposure control (AEC)?
A. To automatically select the appropriate kVp based on body part thickness.
B. To terminate the x-ray exposure when a predetermined amount of radiation has reached the image
receptor.
C. To adjust the mAs based on the patient's body habitus.
D. To eliminate the need for a grid.
Correct Answer : B
Rationale: Automatic Exposure Control (AEC) is a system that uses radiation detectors placed in front of
the image receptor. These detectors measure the amount of radiation reaching the receptor and
automatically terminate the exposure when a pre-set, optimal level of exposure has been achieved,
helping to produce consistent image density. (Domain: Image Production)
Procedures
10. For a routine AP (Anteroposterior) projection of the abdomen, where should the central ray be
directed?
A. At the level of the iliac crests.
B. At the level of the xiphoid process.
, 4
C. At the level of the anterior superior iliac spines (ASIS).
D. At the level of the umbilicus.
Correct Answer : A
Rationale: For a standard AP abdominal x-ray, the central ray (CR) is positioned at the midline of the
patient's body, at the level of the iliac crests. This positioning ensures the entire abdomen is adequately
visualized on the image. (Domain: Procedures)
11. A patient is scheduled for a barium enema (lower GI series). Prior to the exam, the technologist
should confirm that which of the following has been completed?
A. The patient has taken oral contrast the night before.
B. The patient has been NPO (nothing by mouth) for at least 8 hours.
C. The patient has completed the bowel preparation as instructed.
D. The patient has removed all jewelry and metallic objects.
Correct Answer : C
Rationale: For a barium enema, the most critical prerequisite is a clean colon. A proper bowel
preparation is essential to ensure that the colonic mucosa is clear of fecal material, which could
otherwise obscure lesions or cause artifacts in the images. (Domain: Procedures)
12. For an AP projection of the knee, the central ray should be directed to a point:
A. 1/2 inch distal to the apex of the patella.
B. 1/2 inch proximal to the apex of the patella.
C. At the level of the tibial tuberosity.
D. At the level of the fibular head.
Correct Answer : B
Rationale: For a standard AP knee projection, the central ray is centered to a point approximately 1/2
inch (1 cm) distal to the apex of the patella (the lower tip of the kneecap). This positioning ensures the
joint space is opened and properly visualized. (Domain: Procedures)
13. A technologist is about to perform a barium enema on an elderly patient. The patient becomes
tearful and says, "I'm so embarrassed." What is the most appropriate response?
A) "Don't worry, it's a very common procedure."
B) "I understand this can be uncomfortable. We will do everything to protect your dignity."
C) "You shouldn't be embarrassed; we do this all day."
D) "Would you like to cancel and reschedule?"
Correct Answer : B
Rationale: Acknowledging the patient's feelings and reassuring them about dignity and privacy is the
most empathetic and therapeutic response. It validates the patient's emotional state without being
dismissive. Option A minimizes the patient's feelings, option C is dismissive, and option D does not
address the underlying concern.