Written by students who passed Immediately available after payment Read online or as PDF Wrong document? Swap it for free 4.6 TrustPilot
logo-home
Document preview thumbnail
Preview 2 out of 5 pages
Exam (elaborations)

Nicet Water Based Layout Level III EXAM QUESTIONS AND ANSWERS 100% CORRECT!!

Document preview thumbnail
Preview 2 out of 5 pages

A sprinkler is 3 feet away from a gas powered unit heater in a 2,000 square foot garage. What should be the temperature rating of the sprinkler? - ANSWER High temp 286 degrees In a new apartment building where the highest floor for use is 45 feet above the lowest level for fire department access, which type of standpipe is required? - ANSWER wet automatic What is the minimum fire-resistance rating for a fire partition that separates dwelling units in the same building that in constructed of Type VB (5B) construction and a sprinkler system in accordance with International Building Code (IBC) section 903.3.1.1 ? - ANSWER 1/2 hour per IBC 708.3 A contractor submits hydraulic calculations for a wet system with black steel pipe. The calculations are based on a C value of 120. The AHJ rejects the calculations because the local building code requires a value of 100 to be used for wet and dry systems. The contract requires the contractor to follow NFPA 13 and local building codes. What should the contractor do? - ANSWER Revise the calculation to comply with the local code requirements A 45000 square foot building with 40 feet of elevation to the roof has required exit stairways and a Class I manual dry standpipe system. A roof manifold is located 3 feet above the roof. The total amount of friction loss in the pipe is 8 psi. What is the required flow and pressure at the fire department connection (FDC) located 3 feet above finished grade? - ANSWER 750 gpm and 126 psi (2,480 liters per minute and 8.6 bar) A contract has been finalized to relocate upright sprinklers to the pendent position from an exis

Content preview

Nicet Water Based Layout Level III EXAM
QUESTIONS AND ANSWERS 100% CORRECT!!

, Which detail is one purpose of architectural drawings? - ANSWER communicate scope
of work

For fire pump and jockey pump installations, where should the pump controller's
pressure sensing lines be connected? - ANSWER individual from each other

A sprinkler is 3 feet away from a gas powered unit heater in a 2,000 square foot garage.
What should be the temperature rating of the sprinkler? - ANSWER High temp 286
degrees

In a new apartment building where the highest floor for use is 45 feet above the lowest
level for fire department access, which type of standpipe is required? - ANSWER wet
automatic

What is the minimum fire-resistance rating for a fire partition that separates dwelling
units in the same building that in constructed of Type VB (5B) construction and a
sprinkler system in accordance with International Building Code (IBC) section
903.3.1.1 ? - ANSWER 1/2 hour per IBC 708.3

A contractor submits hydraulic calculations for a wet system with black steel pipe. The
calculations are based on a C value of 120. The AHJ rejects the calculations because
the local building code requires a value of 100 to be used for wet and dry systems. The
contract requires the contractor to follow NFPA 13 and local building codes. What
should the contractor do? - ANSWER Revise the calculation to comply with the local
code requirements

A 45000 square foot building with 40 feet of elevation to the roof has required exit
stairways and a Class I manual dry standpipe system. A roof manifold is located 3 feet
above the roof. The total amount of friction loss in the pipe is 8 psi. What is the required
flow and pressure at the fire department connection (FDC) located 3 feet above finished
grade? - ANSWER 750 gpm and 126 psi (2,480 liters per minute and 8.6 bar)

A contract has been finalized to relocate upright sprinklers to the pendent position from
an existing pipe schedule system that includes 3/4-inch ( 20 millimeter) pipe supplying 1
sprinkler. Which is the correct course of action? - ANSWER Replace 3/4-inch pipe with
1 inch use 1/2 nipples no longer than 4 inches, 1-by-1/2 reducing elbows, and new 1
inch drop pipe per NFPA 13 section 30.4.4

A sprinkler manufacturer has a proprietary listing on a sidewall sprinkler capable of a
28-foot-wide discharge spray pattern. Which sprinkler information (if noted on the

Document information

Uploaded on
April 2, 2026
Number of pages
5
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$12.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Luckyexams
3.2
(6)
Sold
30
Followers
2
Items
2288
Last sold
5 days ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions