ACQ EXAM 5 QUESTIONS WITH
CORRECT ANSWERS

What are common digital errors? - Answer- Exposure field too large
Anatomy not centered
Multiple body parts in image
Improper AEC use
Grid errors

What 3 things can digital imaging not fix? - Answer- Underexposure or missing data,
poor positioning, and bad detector selection

What is exposure latitude? - Answer- Margin for exposure error, range of exposures that
can produce an acceptable image for a particular system

For ______ systems, a much wider margin for error is allowed especially in the direction
of overexposure - Answer- Digital

For film based systems, the exposure latitude is - Answer- -30% - +50%

For digital systems, the exposure latitude is - Answer- -50% - +400%

________is not generally apparent in DR and CR images - Answer- Overexposure

It takes at least ________ the normal exposure to saturate a digital image - Answer-
10x

Some systems begin to show mottle at only a ______ reduction in mAs - Answer- 35%

Even though repeated rates have been reduced from 5% to about 3%, a ______
increase in radiation delivered per exam has been demonstrated - Answer- 40-50%

If a CR plate has been fogged prior to using it for an exposure, it will result in - Answer-
An image with poor contrast

Pre-fogging of a CR plate covers - Answer- The entire plate

Prefogging a CR plate will usually cause - Answer- Histogram analysis and EI errors

, T/F: Scatter radiation that occurs during an exposure does usually not result in
histogram analysis or EI errors - Answer- T

Prefogging of a CR plate primarily affects the ______ portions of the image - Answer-
Lighter (leaves no blank white pixels)

__________ can clean up specific fog patterns within the latent image - Answer-
Frequency processing

_______ can target structures of a specific size to eliminate them from the image -
Answer- Frequency processing

When a CR or DR system is installed, the AEC is recalibrated based on the
__________ produced at the selected speed class - Answer- Exposure indicator

If image mottle is a problem during AEC procedures, the _____ should be increased
until sufficient signal is reaching the detector cells - Answer- kVp

Any time AEC is used, off centering of the anatomy can result in - Answer- Image mottle

If grids are not used, patient dose is - Answer- Reduced

Patient dose can be reduced as low as _________ if grids are not used or grid ratios
are reduced - Answer- 1/3 - 1/4

Grids are one method of reducing the - Answer- Amount of noise

Anatomy smaller than _______ should not be done with grids - Answer- 13 cm


AEC controls - Answer- exposure time only (mAs)

Even with AEC, the radiographer must set the - Answer- kVp, mA, detector cell, backup
time/mAs, density control if needed

What is minimum response time (MRT)? - Answer- The shortest time the AEC can
terminate an exposure, minimum time it takes for the electric circuit to detect and react
to radiation

What is the range of MRT? - Answer- 0.002 - 0.02 seconds

The back up mAs or time prevents excessive duration of the exposure to - Answer-
Avoid heat overload on the tube anode and prevent excessive patient exposure

Most modern units have back up times or mAs pre set by the manufacturer but many of
them are - Answer- Excessive (sometimes 20x the average) and inconsistent

Document information

Uploaded on
April 1, 2026
Number of pages
8
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$13.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Perfectscorer
3.6
(75)
Sold
501
Followers
355
Items
9427
Last sold
1 week ago


Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions