MASSACHUSETTS CONSTRUCTION SUPERVISOR LICENSE (CSL) EXAMINATION PREP COMPLETE 150 QUESTIONS WITH 100% VERIFIED ANSWERS ________________________________________ 1. Condensate from cooling coils or evaporators shall be conveyed from the drain pan outlet to: A) The outside B) An approved place of disposal C) A larger pan D) Any of the above Answer: B) An approved place of disposal ________________________________________ 2. What is the minimum thickness of Portland cement mortar that must be applied from the footing to the finish grade of an exterior foundation wall for damp proofing? A) 1-3/8" B) 1" C) 1-1/2" D) 3/8" Answer: D) 3/8" ________________________________________ 3. A Type 4 building is also described as what type of construction? A) Combustible B) Solid C) Heavy timber D) Steel frame Answer: C) Heavy timber ________________________________________ 4. A fall protection plan must include all of the following except: A) Procedures for the rescue of a fallen worker B) Administrative notes C) Maintenance notes D) A competent person to implement and supervise the plan Answer: B) Administrative notes ________________________________________ 5. What is the required R-value for wood frame walls in Massachusetts? A) 13 B) 21 or 15 + 3 C) 19 D) 20 or 13 + 5 Answer: D) 20 or 13 + 5 ________________________________________ 6. In a single-family home, except for kitchens, what is the minimum square footage that a room is considered habitable? A) 70 B) 50 C) 100 D) No minimum Answer: A) 70 ________________________________________ 7. When an occupant load is 50 or more, egress doors shall: A) Swing inward B) Be revolving doors C) Swing in the direction of egress travel D) Be double doors Answer: C) Swing in the direction of egress travel ________________________________________ 8. Handrails shall be provided on at least one side of each continuous run of stairs with ______ or more risers. A) 4 B) 6 C) 12 D) 10 Answer: A) 4 ________________________________________ 9. Ladders must extend ______ feet beyond the eaves or edge of a roof. A) 3 B) 2 C) 4 D) 2.5 Answer: A) 3 ________________________________________ 10. Ferrous metals contain mostly what? A) Zinc B) Iron C) Lead D) Aluminum Answer: B) Iron ________________________________________ 11. Walls that separate sleeping units in the same building must comply with the provisions for: A) Smoke partitions B) Smoke barriers C) Fire partitions D) Fire barriers Answer: C) Fire partitions ________________________________________ 12. Energy code requires that non-conditioned space which is altered to become conditioned space: A) Must be brought into partial compliance B) Must be brought into full compliance C) Nothing is required D) It is not allowed Answer: B) Must be brought into full compliance ________________________________________ 13. Habitable rooms are required to have natural light with an aggregate glazing area that is not less than ______ % of the floor area. A) 10 B) 8 C) 4 D) 6 Answer: B) 8 ________________________________________ 14. Masonry chimney cleanout openings shall be provided within ______ inches of the base of each flue.

Show more Read less
Institution
MASSACHUSETTS CONSTRUCTION SUPERVISOR LICENSE (CSL
Course
MASSACHUSETTS CONSTRUCTION SUPERVISOR LICENSE (CSL

Content preview

MASSACHUSETTS CONSTRUCTION SUPERVISOR LICENSE (CSL)
EXAMINATION PREP COMPLETE 150 QUESTIONS WITH 100%
VERIFIED ANSWERS


1. Condensate from cooling coils or evaporators shall be conveyed from the
drain pan outlet to:
A) The outside
B) An approved place of disposal
C) A larger pan
D) Any of the above
Answer: B) An approved place of disposal


2. What is the minimum thickness of Portland cement mortar that must be
applied from the footing to the finish grade of an exterior foundation wall for
damp proofing?
A) 1-3/8"
B) 1"
C) 1-1/2"
D) 3/8"
Answer: D) 3/8"


3. A Type 4 building is also described as what type of construction?
A) Combustible
B) Solid
C) Heavy timber
D) Steel frame
Answer: C) Heavy timber

,4. A fall protection plan must include all of the following except:
A) Procedures for the rescue of a fallen worker
B) Administrative notes
C) Maintenance notes
D) A competent person to implement and supervise the plan
Answer: B) Administrative notes


5. What is the required R-value for wood frame walls in Massachusetts?
A) 13
B) 21 or 15 + 3
C) 19
D) 20 or 13 + 5
Answer: D) 20 or 13 + 5


6. In a single-family home, except for kitchens, what is the minimum square
footage that a room is considered habitable?
A) 70
B) 50
C) 100
D) No minimum
Answer: A) 70


7. When an occupant load is 50 or more, egress doors shall:
A) Swing inward
B) Be revolving doors

,C) Swing in the direction of egress travel
D) Be double doors
Answer: C) Swing in the direction of egress travel


8. Handrails shall be provided on at least one side of each continuous run of
stairs with ______ or more risers.
A) 4
B) 6
C) 12
D) 10
Answer: A) 4


9. Ladders must extend ______ feet beyond the eaves or edge of a roof.
A) 3
B) 2
C) 4
D) 2.5
Answer: A) 3


10. Ferrous metals contain mostly what?
A) Zinc
B) Iron
C) Lead
D) Aluminum
Answer: B) Iron

, 11. Walls that separate sleeping units in the same building must comply with the
provisions for:
A) Smoke partitions
B) Smoke barriers
C) Fire partitions
D) Fire barriers
Answer: C) Fire partitions


12. Energy code requires that non-conditioned space which is altered to become
conditioned space:
A) Must be brought into partial compliance
B) Must be brought into full compliance
C) Nothing is required
D) It is not allowed
Answer: B) Must be brought into full compliance


13. Habitable rooms are required to have natural light with an aggregate glazing
area that is not less than ______ % of the floor area.
A) 10
B) 8
C) 4
D) 6
Answer: B) 8


14. Masonry chimney cleanout openings shall be provided within ______ inches
of the base of each flue.

Written for

Institution
MASSACHUSETTS CONSTRUCTION SUPERVISOR LICENSE (CSL
Course
MASSACHUSETTS CONSTRUCTION SUPERVISOR LICENSE (CSL

Document information

Uploaded on
March 20, 2026
Number of pages
42
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

  • csl
$15.99
Get access to the full document:

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
maingirose Chamberlain College Of Nursing
View profile
Follow You need to be logged in order to follow users or courses
Sold
9
Member since
3 months
Number of followers
0
Documents
863
Last sold
1 week ago
MaingiRose

THE PREMIUM STUDY RESOURCE HUB – VERIFIED ANSWERS FOR EVERY LEARNER COMPREHENSIVE STUDY GUIDES DESIGNED FOR SUCCESS. EVERY QUESTION NUMBERED. EVERY ANSWER CONFIRMED. DETAILED EXPLANATIONS THAT BUILD UNDERSTANDING. ALL ANSWER CHOICES INCLUDED FOR COMPLETE PREPARATION. CLEAR, ACCURATE, AND EASY TO USE. FORMATTED FOR QUICK REFERENCE AND FAST LEARNING. PERFECT FOR STUDENTS, PROFESSIONALS, AND LIFELONG LEARNERS SEEKING RELIABLE, TRUSTWORTHY MATERIALS. COMPLETE PATIENT CASE ANALYSES WITH SOAP NOTES. COMPREHENSIVE Q&A COLLECTIONS WITH STEP-BY-STEP RATIONALES. TECHNICAL GUIDES WITH PRACTICAL APPLICATIONS. ALL CONTENT VERIFIED FOR ACCURACY. YOUR TRUSTED SOURCE FOR QUALITY STUDY MATERIALS. MASTER YOUR SUBJECTS. STUDY SMARTER. ACHIEVE MORE.

Read more Read less
5.0

2 reviews

5
2
4
0
3
0
2
0
1
0

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions