,RESIDENTIAL ELECTRICIAN EXAM #1
FERROUS METAL ENCLOSURES FOR GROUNDING ELECTRODE CONDUCTORS SHALL BE _____.
A) ELECTRICALLY CONTINUOUS
B) ELECTRICALLY ISOLATED
C) NOT PERMITTED
D) RIGID METAL CONDUIT (RMC) ONLY
CORRECT ANS: A: ELECTRICALLY CONTINUOUS
REF: 250.64(E)
UNLESS LISTED FOR THE CONTROL OF OTHER LOADS, GENERAL USE DIMMER SWITCHES SHALL
ONLY BE USED TO CONTROL _____.
A) SWITCHED RECEPTACLES FOR CORD-CONNECTED INCANDESCENT LUMINAIRES
B) PERMANENTLY INSTALLED INCANDESCENT LUMINAIRES
C) CEILING FANS WITH LUMINAIRES
D) HOLIDAY DECORATIVE LIGHTING
CORRECT ANS: B: PERMANENTLY INSTALLED INCANDESCENT LUMINAIRES
REF: 404.14(E)
ALL 125-VOLT, SINGLE-PHASE, 15- AND 20-AMPERE RECEPTACLES INSTALLED IN RESIDENTIAL
GARAGES SHALL BE _____.
I) PROTECTED BY A LISTED ARC-FAULT INTERRUPTER
II) PROVIDED WITH GROUND-FAULT CIRCUIT-INTERRUPTER PROTECTION
A) I ONLY
B) II ONLY
, C) BOTH I AND II
D) NEITHER I NOR II
CORRECT ANS: B: II ONLY
REF: 210.8(A)(2); 210.12(B)
THE MAXIMUM ALLOWABLE AMPACITY OF SIZE 18 AWG FIXTURE WIRE IS _____ AMPERES.
A) 12
B) 10
C) 8
D) 6
CORRECT ANS: D: 6
REF: TBL. 402.5
A RECEPTACLE OUTLET INSTALLED FOR A GAS OR ELECTRIC CLOTHES DRYER IN THE LAUNDRY
ROOM OF A DWELLING UNIT MUST BE INSTALLED WITHIN AT LEAST _____ FEET OF THE
INTENDED LOCATION OF THE DRYER.
A) 6
B) 4
C) 10
D) 3
CORRECT ANS: A: 6
REF: 210.50(C)