Written by students who passed Immediately available after payment Read online or as PDF Wrong document? Swap it for free 4.6 TrustPilot
logo-home
Document preview thumbnail
Preview 3 out of 23 pages
Exam (elaborations)

Texas Wastewater Treatment Operator Class B Certification – Exam Questions with Correct Answers Study Guide

Document preview thumbnail
Preview 3 out of 23 pages

This document contains exam-style questions with correct answers for preparation for the Texas Wastewater Treatment Operator Class B certification exam. It covers important operational topics such as activated sludge processes, wastewater treatment stages, clarifier operation, sludge handling, disinfection methods, and laboratory analysis used in wastewater plants. The material is structured to help operators review key concepts, operational calculations, and troubleshooting scenarios commonly tested in the Texas licensing examination.

Content preview

WASTEWATER CLASS B




WASTEWATER CLASS B TEXAS EXAM QUESTIONS WITH CORRECT
ANSWERS.

The name of the State Agency responsible for enforcing pollution control laws in
Texas answer >>>> Texas Commission of Environmental Quality


The term pathogenic means answer >>>> Capable of causing disease


The minimum separation between sewer lines and potable water lines is answer
>>>> 9 feet


A licensed wastewater operator is a professional answer >>>> consistently does
best job possible, practices personal safety, strives to improve job knowledge,
strives to keep the plant and collection system in the best appearance and
working order


An important step in testing a sample for Total Suspended Solids is answer >>>>
Filtering a sample


The Biochemical Oxygen Demand (BOD) of a sample is based on answer >>>>
Measuring the dissolved oxygen (DO) used


The results of Biochemical Oxygen Demand (BOD) sample taken at a treatment
plant tells the operator answer >>>> How the plant was operating 5 days ago

,WASTEWATER CLASS B


Which of the following are dangerous gasses that are likely to be present in lift
stations and manholes? answer >>>> Natural gas, gasoline fumes, hydrogen
sulfide and carbon dioxide


A preferred hydraulic method of cleaning sewer lines is answer >>>> Hydro Jet
Cleaner


Ways to reduce bad odors coming from a collection system answer >>>> routinely
cleaning slow running or low flow lines, adding chlorine or hydrogen peroxide to
the collection system


Types of pipe that are commonly used in wastewater collection system answer
>>>> ductile iron, Poly Vinyl Chloride (PVC)


Before entering a confined space, a worker should answer >>>> Use approved
monitoring device and check for the presence of dangerous gasses, ventilate the
space with a blower, wear a safety harness and attach a life line


A properly designed and operated primary sedimentation tank should remove
_____ percent of incoming BOD answer >>>> 30-40%


Devices that may be used to determine the level of sewage in a lift station answer
>>>> air bubbler, floats, electrodes, Acoustic (sonic)


What is the most important role of aerobic bacteria in the treatment of
wastewater? answer >>>> decompose organic matter

, WASTEWATER CLASS B


The hydraulic loading of a trickling filter may be determined by answer >>>> flow
rate and filter area


These can be used to dewater sludge answer >>>> belt press, drying beds, solid
bowl centrifuge, gravity thickener


Most important to providing adequate sewage treatment in a stabilization pond
answer >>>> sunlight, algae, bacteria and time


Offensive and objectionable odors which sometimes occur in trickling filters
usually indicate answer >>>> septic conditions are present


Dissolved Oxygen (DO) in aeration tank of an activated sludge plant should be
maintained at or about answer >>>> 2 to 4 mg/L


Contributes to the infiltration in a collection system answer >>>> breaks in the
main lines, high ground water levels, heavy rains, hydro jet cleaning plugged
mains


When a centrifuge pump loses prime the answer >>>> pump is no longer moving
liquid


A Rotating Biological Contactor (RBC) is answer >>>> fixed firm biological
treatment process


Needs to be checked regularly to properly operate an activated sludge treatment
plant answer >>>> aeration equipment and mixed liquor solids

Document information

Uploaded on
March 14, 2026
Number of pages
23
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$14.39

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Sold
2
Followers
0
Items
798
Last sold
5 months ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions