1. A building designed primarily for business transactions and professional
services is classified under which occupancy group?
A. Group A
B. Group B
C. Group M
D. Group S
,Correct Answer: B. Group B
Explanation: Group B occupancy includes buildings used for office, professional,
and service-type transactions according to the International Building Code (IBC).
2. The minimum width of an exit access corridor in a Group B occupancy with
an occupant load of more than 50 is:
A. 36 inches
B. 40 inches
C. 44 inches
D. 48 inches
Correct Answer: C. 44 inches
Explanation: IBC requires corridors serving an occupant load greater than 50 to
have a minimum width of 44 inches.
3. A fire-resistance rating for a structural column supporting a floor in Type I
construction is typically:
A. 1 hour
B. 2 hours
C. 3 hours
D. 4 hours
Correct Answer: D. 4 hours
Explanation: Type I construction requires major structural elements such as
columns to have a 4-hour fire-resistance rating.
4. The maximum travel distance in a sprinklered Group B occupancy is
generally:
A. 200 feet
B. 250 feet
C. 300 feet
D. 350 feet
Correct Answer: C. 300 feet
,Explanation: The IBC allows travel distance up to 300 feet for sprinklered Group B
buildings.
5. Which occupancy classification includes retail stores and shops?
A. Group B
B. Group F
C. Group M
D. Group S
Correct Answer: C. Group M
Explanation: Mercantile occupancy includes retail stores and shops selling goods.
6. The minimum number of exits required from a space with an occupant load
of 75 is:
A. 1
B. 2
C. 3
D. 4
Correct Answer: B. 2
Explanation: Spaces with occupant loads exceeding 49 must have at least two
exits.
7. The minimum headroom clearance for means of egress is:
A. 6 feet 4 inches
B. 6 feet 6 inches
C. 7 feet
D. 7 feet 6 inches
Correct Answer: C. 7 feet
Explanation: IBC requires at least 7 feet of vertical clearance in means of egress.
8. Fire partitions used to separate dwelling units in commercial mixed-use
buildings must have a minimum rating of:
, A. 30 minutes
B. 1 hour
C. 2 hours
D. 3 hours
Correct Answer: B. 1 hour
Explanation: Fire partitions separating dwelling units must typically be 1-hour fire-
resistance rated.
9. The required slope for accessible ramps is no steeper than:
A. 1:10
B. 1:12
C. 1:16
D. 1:20
Correct Answer: B. 1:12
Explanation: Accessibility standards limit ramp slope to a maximum of 1:12.
10.A door in the means of egress must swing:
A. Against the direction of travel
B. In any direction
C. In the direction of egress travel when occupant load exceeds 50
D. Only inward
Correct Answer: C. In the direction of egress travel when occupant load exceeds
50
Explanation: Doors must swing in the direction of egress travel when serving
occupant loads greater than 50.
11.Fire walls must extend from the foundation to:
A. The ceiling only
B. The underside of the roof sheathing or deck
C. Mid-height of the roof
D. Any structural beam