Worksheet 3
1. Bone marrow aspiration biopsy obtained via needle from posterior iliac
crest, left side.
07DR3ZX
2. Open excision of the entire right axillary lymph node chain.
07T50ZZ
3. Total thymectomy performed via open approach.
07TM0ZZ
4. A patient had a gastroscopy done for diagnostic purposes.
0DJ68ZZ
5. Code the following case study. One code is required.
Preoperative Diagnosis: Age-related cataract of right eye
Postoperative Diagnosis: Age-related cataract of right eye
Procedure: Cataract removal and insertion of lens
Lens: Bausch and Lomb MX60E, Power +21.5 diopter, serial number:
1234567 EOXP
Procedure Notes: The patient was brought to the operating room and
prepped and draped in the usual sterile manner. A wire lid speculum was
placed in the eye. The anterior chamber was filled with viscoelastic and a
corneal incision was made. The anterior chamber was entered with the
Utrata forceps. Mechanical dilation was performed, and the lens was freed.
Phacoemulsification was performed with the Nagahara chopper in a stop and
go fashion. All cortical material was removed. A 21.5 diopter MX60E lens was
placed. The wounds were hydrated and the pupil was noted to constrict
equally and round. Lid speculum was removed. Vigamox were given to the
patient who left the operating room in good condition.
ICD-10-PCS code:
Answer
08RJ3JZ
1. Bone marrow aspiration biopsy obtained via needle from posterior iliac
crest, left side.
07DR3ZX
2. Open excision of the entire right axillary lymph node chain.
07T50ZZ
3. Total thymectomy performed via open approach.
07TM0ZZ
4. A patient had a gastroscopy done for diagnostic purposes.
0DJ68ZZ
5. Code the following case study. One code is required.
Preoperative Diagnosis: Age-related cataract of right eye
Postoperative Diagnosis: Age-related cataract of right eye
Procedure: Cataract removal and insertion of lens
Lens: Bausch and Lomb MX60E, Power +21.5 diopter, serial number:
1234567 EOXP
Procedure Notes: The patient was brought to the operating room and
prepped and draped in the usual sterile manner. A wire lid speculum was
placed in the eye. The anterior chamber was filled with viscoelastic and a
corneal incision was made. The anterior chamber was entered with the
Utrata forceps. Mechanical dilation was performed, and the lens was freed.
Phacoemulsification was performed with the Nagahara chopper in a stop and
go fashion. All cortical material was removed. A 21.5 diopter MX60E lens was
placed. The wounds were hydrated and the pupil was noted to constrict
equally and round. Lid speculum was removed. Vigamox were given to the
patient who left the operating room in good condition.
ICD-10-PCS code:
Answer
08RJ3JZ