A mechanical splice must achieve: correct answers 125% of the grade strength of the bar

After initial curing is complete, sample cylinders should be maintained at a temperature between:
correct answers 73.5 +/- 3.5 degrees

The ties of a cast-in-place prestressed concrete beam not exposed to weather or permanently cast
against earth shall have a minimum concrete cover of: correct answers 1 inch

An acceptable reinforcing steel support mechanism for a 24-inch deep footing are: correct
answers 1. Precast dobie blocks X
2. Large, solid pieces of glass
3. Masonry CMU pieces
4. Wooden blocks

All of the following are true except: correct answers 1. Minimum concrete cover for bundled
bars of any size need not be greater than 2 inches, unless they are in a member that's permanently
cast against earth
2. Specified concrete cover for headed shear stud reinforcement shall not be less than the cover
requirements for the member in which the stud reinforcement is located
3. Concrete cover for flexural members, walls, and compression members with an effective depth
of 8-inches can vary -3/8 of an inch
4. Concrete cover for members in highly corrosive environments will typically remain the same
as cast against earth

Bars must be tied in place to avoid displacement during concrete placement. The following is not
acceptable for securing intersections: correct answers 1. Annealed tie wire
2. Stainless steel tie wire
3. Plastic clips
4. Welding X

The minimum clear distance required between a mat of #9 bars closely spaced together is:
correct answers 1. 3/4 inch
2. 1 inch
3. 1`-1/8 inch X
4. 1-1/2 inch

Depending upon the jurisdiction, the special inspector is required to send their final reports to the
building official and: correct answers 1. The design professional in responsible charge X
2. The building official only
3. The general contractor, stating their work met compliance
4. The architect of record

Pipes in concrete should have a minimum concrete cover of ______________________ when
exposed to earth or weather. correct answers 1. 3/4 inch

, 2. 1 inch
3. 1-1/2 inches
4. 3 inches

The letter A" following the type of Portland cement denotes: correct answers 1. A finer grade of
cement
2. Compatibility with porous aggregate
3. Use for concrete require air entrainment X
4. Excessive heat during the hydration process

Reinforcing steel should be free of: correct answers 1. Deformations
2. Light rust'
3. water
4. Oil, grease, mud or other foreign substances

Retampering is allowed when: correct answers Approval is given by the engineer of record

When consolidating the concrete for a 6x12 cylinder by ridding, how many ridding strokes are
required to complete each lift? correct answers 25

The duties of a special inspector include all of the following except: correct answers Issuing stop
work notices

Standing water in a footing or other places of concrete deposit shall be removed, unless: correct
answers A Tremmie is used

The maximum initial curing temperature of concrete specimens allowed is correct answers 80
degrees

The minimum slump allowed in a mix that has a designation of a 4-inch max slump is: correct
answers 1 1/2 inches

The minimum temperature of concrete when placing into an 18-inch footing when the ambient
temperature is 35 degrees during discharge is: correct answers 50 degrees

A standard hook for a #6 bar with a 180 degree bend shall have a minimum extension of: correct
answers 3 inches

The clear spacing between spiral reinforcing shall correct answers Not be less than 1 inch; not
exceed 3 inches

The maximum bar size bundled in beams is correct answers #11 bar

When preparing cylinders for initial curing, the following should be used: correct answers A
method controlling temperature in moisture

Document information

Uploaded on
February 20, 2026
Number of pages
5
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$10.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
SirAnton
3.7
(118)
Sold
791
Followers
438
Items
40035
Last sold
1 week ago


Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions