_______________ is a structure containing one or more vertical or near vertical
passageways for conveying flue gases to the outside atmosphere. - ANSWER-A
chimney. NFPA 211 3.3.28.1.1
A barometric draft regulator if used shall be installed _______? - ANSWER-In the same
room or enclosure as the appliance. NFPA 211 9.11.3
A barometric draft regulator, if used, shall be installed where? - ANSWER-In the same
room or enclosure as the appliance in such a manner that no difference in pressure
between the air in the vicinity of the regulator and the combustion air supply will be
permitted. NFPA 211 9.11.3
A chamber in which heat resulting directly from the combustion of fuel is transferred
through the walls of the chamber to air passing through is called a _______? -
ANSWER-Heat exchanger NFPA 211 3.3.87
A chimney cap is used to ________? - ANSWER-Provide a protective covering for the
top of the chimney to prevent entry of rain, snow, animals and birds and to prevent
downdrafts.
A chimney connector shall be? - ANSWER-As short and straight as practicable. NFPA
211 9.3
A fixed or removable ring tube or lining usually located in the hole where the chimney
connector or vent connector passes through a wall or enters a chimney or vent is called
a ? - ANSWER-Thimble. NFPA 211 3.3.132
A fuel-burning appliance for heating water to a temperature not more than 200F is
known as a _____________? - ANSWER-Water heater. NFPA 211 3.3.88.4
A self-contained heating appliance that is intended for the heating of a space in which it
is installed is known as a ______? - ANSWER-Unit heater. NFPA 211 3.3.88.3
A vertical or nearly vertical vent composed of factory-built components conveying gases
from oil and gas appliances or their vent connectors to the outside atmosphere. -
ANSWER-Type L vent. NFPA 211 3.3.142.3
Questions and Answers Rated A+
_______________ is a structure containing one or more vertical or near vertical
passageways for conveying flue gases to the outside atmosphere. - ANSWER-A
chimney. NFPA 211 3.3.28.1.1
A barometric draft regulator if used shall be installed _______? - ANSWER-In the same
room or enclosure as the appliance. NFPA 211 9.11.3
A barometric draft regulator, if used, shall be installed where? - ANSWER-In the same
room or enclosure as the appliance in such a manner that no difference in pressure
between the air in the vicinity of the regulator and the combustion air supply will be
permitted. NFPA 211 9.11.3
A chamber in which heat resulting directly from the combustion of fuel is transferred
through the walls of the chamber to air passing through is called a _______? -
ANSWER-Heat exchanger NFPA 211 3.3.87
A chimney cap is used to ________? - ANSWER-Provide a protective covering for the
top of the chimney to prevent entry of rain, snow, animals and birds and to prevent
downdrafts.
A chimney connector shall be? - ANSWER-As short and straight as practicable. NFPA
211 9.3
A fixed or removable ring tube or lining usually located in the hole where the chimney
connector or vent connector passes through a wall or enters a chimney or vent is called
a ? - ANSWER-Thimble. NFPA 211 3.3.132
A fuel-burning appliance for heating water to a temperature not more than 200F is
known as a _____________? - ANSWER-Water heater. NFPA 211 3.3.88.4
A self-contained heating appliance that is intended for the heating of a space in which it
is installed is known as a ______? - ANSWER-Unit heater. NFPA 211 3.3.88.3
A vertical or nearly vertical vent composed of factory-built components conveying gases
from oil and gas appliances or their vent connectors to the outside atmosphere. -
ANSWER-Type L vent. NFPA 211 3.3.142.3