24 hours - ANS All fire alarm systems and supervising stations require _____________ hours
of standby power?


5 minutes - ANS Commercial fire alarm (premises, remote, central, proprietary, auxiliary)
require __________ minutes of alarm power?


4 minutes - ANS Household fire alarm systems require __________ minutes of alarm power?


20% - ANS Battery calculations require _________% of additional safety margin?


10 seconds - ANS Secondary power shall switch within ______________ seconds?


90 seconds - ANS Supervisory signals shall indicate within ____________ seconds?


200 seconds - ANS Trouble signals shall indicate within ____________ seconds?


85-110% - ANS Equipment shall operate at ________ to _________% voltage at 32-120 deg F
and 85% humidity?


1 @COPYRIGHT 2025/2026 ALLRIGHTS RESERVED.

,True - ANS True or False: Each floor shall be a separate zone?


True - ANS True or False: If system serves multiple buildings, each building shall be zoned
separately?


False - ANS True or False: If system serves multiple buildings, all the buildings shall be zoned
as one entity?


Class A - ANS What class circuit? Redundant (return path), operates with single ground of
open


Class B - ANS What class of circuit? Single pat, operates up to single open, EOLR on IDC and
NAC


Class C - ANS What class of circuit? Multiple paths, no supervision of paths, operation verified
by receipt of signal


Class D - ANS What class circuit? Fail-safe operation


Class E - ANS What class circuit? No supervision


Class X - ANS What class circuit? Class A SLC which operates with short, fault isolator per
device


Class N - ANS What class circuit? Network (ethernet), dual cable/fiber to each ethernet
device or segment.


42 inches - ANS The operable part of a manually actuated alarm initiating device shall be not
less than ________ inches AFF?


2 @COPYRIGHT 2025/2026 ALLRIGHTS RESERVED.

,48 inches - ANS The operable part of a manually actuated alarm initiating device shall be not
more than ________ inches AFF?


5 feet - ANS A manually actuated alarm initiating device shall not be more than
_______________ feet from the exit?


8 feet - ANS Rod and pipe electrodes shall not be less than ____________ feet in length?


36 inch (3 feet) - ANS Smoke alarms and smoke detectors shall not be installed within a
________________ inch horizontal path from the supply registers of a forced air heating or
cooling system


80 inches - ANS Wall mounted visible notification appliances should be mounted so that the
entire lens is not less than _____________ inches?


96 inches - ANS Wall mounted visible notification appliances should be mounted so that the
entire lens is not more than _____________ inches?


6 inches - ANS In rooms that are low that do not allow for mounting over 80 inches, wall-
mounted visible notification appliances should be mounted __________ inches from the
ceiling?


30 feet - ANS Ceiling mounted strobes are allowed if ceilings are under ___________ feet?


4 inches - ANS A ceiling shall be treated as a smooth ceiling if the beams project no more
than _______________ inches from the ceiling?


4 inches - ANS Spot-type heat detectors shall be located on the ceiling not less than
__________ inches from the sidewall?


12 inches - ANS Spot-type heat detectors located on the sidewall shall be no greater than
______ inches from the ceiling?
3 @COPYRIGHT 2025/2026 ALLRIGHTS RESERVED.

, 4 inches - ANS Spot-type heat detectors located on the sidewall shall be no less than
________ inches from the ceiling?


System Owner - ANS The _______ is/are responsible for keeping all installation documents
related to their installations.


Written contract - ANS Inspections, testing, or maintenance shall be permitted to be done by
a person or organization other then the owner if conducted under a __________.


Semiannually - ANS When are visible alarm notification appliances required to be tested?


Semiannually - ANS When are audible alarm notification appliances required to be tested?


Semiannually - ANS How often should there be a visual inspection of heat detectors?


15 minutes - ANS How many minutes are required for a battery to provide in alarm if the
system is an 'emergency voice alarm communication system' (EVACS) or 'mass notification
system' (MNS)?


4 - ANS According to OSHA, a portable ladder shall support at least _______ times the
maximum intended load?


Before initial use - ANS Ladders must be inspected __________ to identify any visible defects
that could cause employee injury?


32-120 F - ANS What is the optimal battery operating range in deg F?


15% - ANS If partitions extend beyond ___________ % of the ceiling height, the spaces
separated by the partitions are considered separate rooms.


4 @COPYRIGHT 2025/2026 ALLRIGHTS RESERVED.

Written for

Institution
NICET FIRE ALARM
Course
NICET FIRE ALARM

Document information

Uploaded on
February 13, 2026
Number of pages
44
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

$13.99
Get access to the full document:

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Fyndlay Kaplan University
View profile
Follow You need to be logged in order to follow users or courses
Sold
419
Member since
2 year
Number of followers
81
Documents
20069
Last sold
4 hours ago
Scholar\'s Sanctuary.

Explore a Vast Collection of Finely Made Learning Materials.

3.7

75 reviews

5
33
4
11
3
15
2
6
1
10

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions