CERTIFICATION (EVITP) EXAM / EVITP ACTUAL EXAM 2026
COMPLETE ACCURATE TEST EXAM APPROVED QUESTIONS AND
CORRECT DETAILED ANSWERS WITH RATIONALE (100% CORRECT
VERIFIED SOLUTIONS) LATEST UPDATED VERSION |GUARANTEED
PASS A+ (BRAND NEW!) |FULL REVISED EXAM
1) According to NEC Article 625, the conductors supplying Electric Vehicle
Supply Equipment (EVSE) must have an ampacity of at least what percentage
of the EVSE’s maximum load?
a) 100%
b) 115%
c) 125%
d) 150%
correct answer: b 125%
rationale: NEC 625.41 treats EVSE as a continuous load; continuous loads require
conductor sizing at 125% of the load per NEC definitions.
2) When installing a Level 2 EVSE on a dedicated 40-amp circuit in a new
dwelling unit garage, what is the minimum size THHN copper conductor
required?
a) 10 AWG
b) 8 AWG
c) 6 AWG
d) 4 AWG
correct answer: b 8 wag
rationale: 40 A × 1.25 = 50 A continuous load. Per NEC Table 310.16, 8 AWG
copper at 75 °C is rated 50 A, meeting the continuous requirement.
3) A commercial installation plans for ten (10) identical Level 2 EVSE units
with a nameplate of 32 amps at 208 V each. Using NEC Table 625.42 demand
factors, what is the calculated feeder load?
a) 256 A
b) 320 A
c) 200 A
,d) 192 A
correct answer: d 192 a
rationale: Each unit continuous load is 32 A × 1.25 = 40 A. Demand factors reduce
total load for multiple units per NEC 625.42; the calculated feeder load is 192 A.
4) EVSE installed outdoors in a parking lot and subject to physical damage
from vehicles must be protected by which measure per NEC?
a) Underground vault
b) Guard posts or curbs
c) Dedicated concrete island only
d) Relocation away from vehicles
correct answer: b guard posts or curbs
rationale: NEC requires overhead and physical-damage protection; guard
posts/curbs placed per code protect equipment from vehicles.
5) The disconnecting means for an EVSE in a public garage must be:
a) Integral only
b) Within sight and readily accessible
c) At the main service panel only
d) A Type HS fuse disconnect
correct answer: b within sight and readily accessible
rationale: NEC 625.18 specifies a disconnecting means for ungrounded
conductors that must be within sight and easily accessible to the EVSE.
6) Installation of EVSE at an existing building is worth how many LEED
points?
a) 1
b) 3
c) 11
d) 15
correct answer: d 15
rationale: EVITP practice exams note that EVSE installations can contribute
significant LEED points when optimizing sustainability features.
, 7) According to ADA guidelines, what percentage of general parking spaces
should be accessible when planning an EVSE installation?
a) 2%
b) 4%
c) 6%
d) 8%
correct answer: b 4%
rationale: ADA standards require a minimum percentage of accessible parking;
4% is commonly cited for general lots applicable to EVSE siting.
8) What process ensures mechanical, electrical, and other building systems
are installed, tested, and perform interactively per design documents?
a) A one-line
b) Commissioning
c) Walk-through
d) Estimating
correct answer: b commissioning
rationale: Commissioning validates that all installation systems function
according to the design and specifications.
9) Adequate site lighting at an EVSE location increases:
a) Aesthetics only
b) Theft risk
c) Safety
d) Installation complexity
correct answer: c safety
rationale: Sufficient lighting enhances user safety and reduces hazards in EVSE
areas.
10) Installing electric vehicle charging equipment may ______ public
perception of a business.
a) improve
b) minimize
c) reduce
d) none of the above