neutral point - CORRECT ANSWER - The common point on a wye-
connection in a polyphase system or midpoint on a single phase, 3-wire system,
or midpoint of a single phase portion of a 3-phase delta system, or a midpoint of
a 3-wire, direct current system


In the NEC the words ___________indicate a mandatory requirement -
CORRECT ANSWER - Shall or shall not


On a four wire Delta connected system with a midpoint of one phase winding is
grounded, only the conductor or bus bar having a higher phase voltage the
ground shall be durably and permanently marked by an outer finish that is
_______ in color or by other effective means. Such Identification shall be
placed at each point on the system where connection is made if the grounded
conductor is also present. - CORRECT ANSWER - Orange


The required working space for access to live parts operating at 300 V to
ground, where there are exposed live parts on one side and grounded parts on
the other side is ____________. - CORRECT ANSWER - 3 feet 6 inches


The dimensions of working space for access to live parts operating at 300 V,
nominal to ground, where there are expose live parts on both sides of the
workspace is________________. - CORRECT ANSWER - 4 feet


110.26 A1- Dead front assemblies working space - CORRECT ANSWER -
30" for non-electrical parts
36" for electrical parts

,The working space in front of the electrical equipment shall not be less than
_______wide, or of the width of the equipment, whichever is greater. -
CORRECT ANSWER - 30"


Large equipment - CORRECT ANSWER - 1200 A or greater and over 6 feet
wide


Large equipment means of egress - CORRECT ANSWER - Two means of
egress 24" wide by 6.5 feet tall unless the following condutions are met


1) unobstructed egress
2) Double the workspace


Headroom shall not be less than _______. - CORRECT ANSWER - 6.5 feet or
the height of the equipment


Live parts of electrical equipment operating at ______volts or more she'll be
guarded against accidental contact or approved enclosures or by any of the
following means - CORRECT ANSWER - 50 volts
4) by elevation of 8 feet or more above the floor or other working surface


A fence shall not be less than ______feet in height - CORRECT ANSWER - 8
feet


One entrance to enclosures for electrical installations as described in 110.31 not
less than _______wide and _________high shall be provided to give access to
the working space around the electrical equipment - CORRECT ANSWER -
30 inches and 6.5 feet

,Network compartments shall have at least ________means of access. Each door
she'll have an access that leads to a legal exit. - CORRECT ANSWER - Two


Where rear access is required to work on deenergized parts on the back of
enclosed equipment a minimum working space of __________horizontally shall
be provided - CORRECT ANSWER - 30 inches


All non-current carrying metal parts of electrical equipment and all metal
raceways and cable shall be solidly grounded and bonded to all metal pipes in
rails at the portal and the intervals not exceeding _____________throughout the
tunnel. - CORRECT ANSWER - 1000 feet


Manhole workspace for cabling-A clear workspace not less than _______wide
shall be provided were cables are located on both sides and not less than
_______were cables are only on one side. - CORRECT ANSWER - 3 feet
2-1/2 feet


Access to manhole dimensions. Rectangular access openings shall not be less
than _______. Round access openings in a manhole shall be not less than
______inches in diameter - CORRECT ANSWER - 26" x 22"
26"


Manhole openings for personnel shall be located where they are not directly
above electrical equipment or conductors in the enclosure. Where this is not
practiceable either a ________or a _______shall be provided. - CORRECT
ANSWER - Protective barrier of fixed ladder


And insulated grounded conductor of _____or smaller shall be identified by a
continuous white or gray outer finish or by three continuous white stripes on
other than green insulation along its entire length. - CORRECT ANSWER - 6
awg

, Manhole covers shall be over ______pounds or otherwise designated to require
the use of tools to open. - CORRECT ANSWER - 100 pounds


The grounded conductors of other systems shall have a different outer covering
conforming to 200.6A or 200.6B or by an outer covering of ______or
_______with a readily distinguishable colored stripe other than green running
along the insulation - CORRECT ANSWER - White or gray


Where conductors of different systems are installed in the same race way, one
system she'll have a neutral having an outer covering of white or natural gray
and each other system having a neutral shall have an another covering of -
CORRECT ANSWER - White with colored Stripe other than green or
distinguish by other suitable approved means


For screw shell devices with attach leads the conductor attached to the screw
shell shall have a _______or ________finish. - CORRECT ANSWER - White
or gray


In addition to the number of branch circuits required by other parts of the
section _______or more 20 A small appliance branch circuits shall be provided
for all receptacle outlets specified by 210.52B. - CORRECT ANSWER - Two


An individual branch circuit shall be provided for each _________receptacle
required by 210.52 I. - CORRECT ANSWER - Air-Conditioning


Branch circuits required in a dwelling unit. - CORRECT ANSWER - 1) small
appliance branch circuit
2) laundry branch circuit
3) bathroom branch circuits
4) Air-Conditioning (NYC AMEND)

Document information

Uploaded on
January 31, 2026
Number of pages
51
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$22.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
tutorlorghon
4.7
(253)
Sold
759
Followers
18
Items
6132
Last sold
11 hours ago


Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions