C1064/C1064M - ANSWER Standard test method for temperature for concrete
C172/C172M - ANSWER Standard practice for sampling concrete
C143/C143M - ANSWER Standard testing for Slump
C138/C138M - ANSWER Standard test method for Density (unit weight), yield, and air
content (Gravimetric)
C231/C231M - ANSWER Standard test method for Air Content (Pressure Method)
C173/C173M - ANSWER Standard test method for Air Content (Volumetric Method)
C31/C31M - ANSWER Stand Practice for making and curing conrete test specimens in field
C1064/C1064M
,The end of hte temperature sensing portion of hte temperature measuring device is submerged
a minimum of _______ or _______" into the freshly mixed concrete - ANSWER 75mm or 3"
C1064/C1064M
The Temperature measuring device shall be capable of accurately measuring hte temperature of
Freshly mixed concrete to _________ throughout a range of _________ - ANSWER 0.5
degree C (1 degree F) and 50 degree C (30fF - 120F)
C1064/C1064M
The temperature measuring device shall be verified___________, or whenever there is a
question of___________ - ANSWER Annually or Accuracy
C1064/C1064M
The temperature of concrete may be measured in a wheelbarrow T/F? - ANSWER True
C1064/C1064M
The temperature of concrete may be measured in a wall form T/F - ANSWER True
C1064/C1064M
A composite sample of concrete is required EVEN if the only purpose for obtaining hte sample is
to determine the temperature T/F - ANSWER False
C1064/C1064M
What must be done to the sample container prior to sampling hte concrete - ANSWER
Dampened (With Water)
C1064/C1064M
, What must be done to the concrete surrounding the temperature masuring device after the
device is submerged in the fresh concrete? - ANSWER Gently press the concrete around the
temperature masuring device at the surface of the concrete
C1064/C1064M
How long must the temperature measuring device remain in the freshly mixed concrete? -
ANSWER 2 min, no more than 5 min
C1064/C1064M
After the temperature of the concrete is read, what is then required - ANSWER Recording
the Temperature
C1064/C1064M
The temperature of the concrete is reported to the nearest - ANSWER 0.5 degree C (1 degree
F)
C1064/C1064M
According to the test method C1064/C1064M, what is one reason to take the temperature of
the concrete - ANSWER Verify conformance to specified requirement for temperature of
concrete
C1064/C1064M
A maximum temperature of Freshly mixed concrete is specified in Test method of
C1064/C1064M - ANSWER FALSE, its in the spec from the owner
C1064/C1064M
The sample of concrete used for temperature determination must be rodded 25 times T/F -
ANSWER FALSE