Engineered truss drawings must be submitted and approved by the building official prior to
installation.
false
All stairs must have a minimum width in 36" above the handrails.
true
Wood structural panel box headers have specific criteria in the IRC code book.
false
Treads on spiral stairs do not need not be identical but must be at least 6.75" in length.
featuring complete and verified questions and answers designed to Cm
strengthenCm
3236 Exam3236
1.pdfExam 1 Cm 3236 Exam 1.pdf
,featuring complete and verified questions and answers designed to Cm
strengthenCm
3236 Exam3236
1.pdfExam 1 Cm 3236 Exam 1.pdf
true
Reinforcement within a slab on grade must remain in place between the center and the upper
third of the slab for the duration of concrete placement.
true
A soil report is the basis for foundation design in order that prescriptive measurements may be
used.
false
Minimum headroom for stairs is 7' measured vertically from the sloped line adjoining the tread
nosing or the floor surface of the landing or platform on that portion of the stairway.
false
The ends of each joist, beam, or girder must have at least 14" of bearing on wood and not less
than 18" bearing on masonry or concrete oron a sill plate of at least 20" nominal thickness with
a nominal bearing area of 24 in2.
featuring complete and verified questions and answers designed to Cm
strengthenCm
3236 Exam3236
1.pdfExam 1 Cm 3236 Exam 1.pdf
,featuring complete and verified questions and answers designed to Cm
strengthenCm
3236 Exam3236
1.pdfExam 1 Cm 3236 Exam 1.pdf
true
Address numbers must be plainly legible and visible from the street or road.
false
The minimum thickness of masonry bearing walls more than one story shall be 10" .
false
Joists shall be lightly supported by half-depth solid blocking less than 2" nominal thickness.
false
Floodplain inspections must be conducted in every building and must be completed before the
permit work is completed.
featuring complete and verified questions and answers designed to Cm
strengthenCm
3236 Exam3236
1.pdfExam 1 Cm 3236 Exam 1.pdf
, featuring complete and verified questions and answers designed to Cm
strengthenCm
3236 Exam3236
1.pdfExam 1 Cm 3236 Exam 1.pdf
false
Engineering designs must demonstrate components inside and outside the scope of non-
conventional framing.
false
A plans examiner does the first step of the construction process by reviewing requirements set
up in the IRC code book.
true
Alternatives to standard anchor bolts may be used according to the manufacturer's
specifications and installation instructions if they have been listed, tested, and approved in the
local jurisdiction.
false
Each sleeping room, crawl spaces and inhabitable attics must have smoke alarms installed.
featuring complete and verified questions and answers designed to Cm
strengthenCm
3236 Exam3236
1.pdfExam 1 Cm 3236 Exam 1.pdf