IAHCSMM CRCST ACTUAL QUESTIONS AND ANSWERS
RATED A+
✔✔central service technician should log receipt of loaner instrumentation and implants
with information including. - ✔✔Date / Time.
delivery person.
receiving person.
Doctors name.
Patients name.
number of trays.
number of implants.

✔✔prion - ✔✔virus-like infectious agents that cause a variety of neurodegenerative
diseases in humans and animals, including scrapie in sheep and goats, bovine
spongiform encephalopathy in cattle, and cretzfeldt-jakob disease in humans.

✔✔seals tamper evidnet - ✔✔sealing methods for sterile packaging that allow users to
determine if the packaging has been opened.

✔✔two categories of sterility packaging. - ✔✔reusable.
disposable.

✔✔objectives of packaging process - ✔✔allow penetration of chosen sterilant.
maintain sterility of package contents.
allow for being opened aseptically.

✔✔Reusable sterilization materials - ✔✔woven textiles.
rigid sterilization containers.

✔✔disposable sterilization materials. - ✔✔pouches.
nonwoven wrap.

✔✔muslin - ✔✔wide variety of plain-weave cotton or cotton/polyester fabrics having
approximately 140 threads per square inch.

✔✔superheating - ✔✔condition that arises when steam is at a temperature which
exceeds that of saturated steam at the same pressure

✔✔linen packs size limit - ✔✔12x12x12, weight no more than 12 lbs, max density not to
exceed 7.2 lbs

✔✔packaging used for steam sterilization - ✔✔must be capable of withstanding high
temps of 250-270-275, must allow air removal and steam penetration, and must permit
drying.

,✔✔packaging used for ETO - ✔✔allow adequate of gas sterilant penetration and
removal of gas reside "aeration"

✔✔packaging used for dr heat sterilization - ✔✔must be able to tolerate 2-3 hrs of 320-
400 degrees.

✔✔packaging used for gas plasma - ✔✔must be able to tolerate deep vacuum draw,
with out absorbing the sterilant.

✔✔rigid container system - ✔✔instrument containers that hold medical devices during
sterilization and also protect devices from contamination during storage and transport

✔✔wet-pack - ✔✔containers with moisture, after the sterilization process is completed.

✔✔kraft-type papers - ✔✔a medical grade paper packaging material used for numerous
sterilization applications.

✔✔SMS spunbond-meltblown-spunbond - ✔✔non woven packaging material which is
the most popular flat wrap.

✔✔papers/pouches that contain cellulose; - ✔✔cannot be used in gas plasma sterilizers
because cellulose absorbs the sterilant and reduces penetration of sterilant.

✔✔paper plastic pouches/SMS wraps - ✔✔acceptable for use with steam and EtO
sterilization processes.

✔✔spunbond polyolefin-plastic/SMS wraps - ✔✔used for gas plasma sterilization.
Referred to as tyvek pouches, contains no cellulosic materials therefore compatible with
gasplasma/Hydrogen peroxide.

✔✔basin sets should not exceed - ✔✔7 lbs

✔✔wicking material - ✔✔an approved absorbent material that allows for air removal,
steam penetration and facilitates drying.

✔✔package labeling should include - ✔✔description of contents.
initials of assembler.
lot control number.
sterilizer ID and cycle.
Date/Time.

✔✔packaging materials should be held; - ✔✔at room temperature 64°F-72°F, humidity
ranging from 35% - 70% for a minimum of two hours before sterilization.

, ✔✔wrapped pans of instruments should not exceed. - ✔✔16 lbs

✔✔containerized instrument sets should not exceed - ✔✔25 lbs

✔✔sterility time related - ✔✔specific expiration date is reaached

✔✔sterility event related - ✔✔considered sterile unless the integrity of the packaging is
compromised or suspected of being compromised by an event regardless of expiration
date.

✔✔FIFO - ✔✔first in first out.

✔✔point of use processing - ✔✔occurs when a medical device is processed
immediately before use, and/or close to the patient care area

✔✔flash sterilization / IUSS - ✔✔process by which unwrapped instruments are sterilized
for immediate use when an emergency situation arises.

✔✔3 agencies that have established standards, guidelines, and recommendations for
IUSS - ✔✔AAMI.
AORN.
Joint commission.

✔✔Flash/IUSS cycles - ✔✔gravity.
pre-vacuum.
express.

✔✔commun IUSS exposure times - ✔✔3.
4.
10.

✔✔IUSS gravity cycle.
single instrument comprised of metal and without lumens. - ✔✔3 minutes @ 270°F

✔✔IUSS gravity cycle.
complex or lumened instruments, mixed load - ✔✔10 minutes @ 270°F

✔✔preset express cycle - ✔✔4 minutes @ 270°F with 3 minutes drying time, total cycle
time of 12 minutes.

✔✔pre-vacuum load of mixed materials, or items with lumens - ✔✔4 minutes @ 270°F

Document information

Uploaded on
January 8, 2026
Number of pages
17
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$12.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
BOARDWALK
3.5
(41)
Sold
283
Followers
10
Items
32850
Last sold
19 hours ago


Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions