100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.6 TrustPilot
logo-home
Exam (elaborations)

Q 01 FDNY Exam Newest /Q 01 FDNY Exam Preparation/Q 01 FDNY Practice Exam With Complete Questions And Correct Detailed Answers (Verified Answers) |Already Graded A+|Brand New Version!!

Rating
-
Sold
2
Pages
31
Grade
A+
Uploaded on
06-01-2026
Written in
2025/2026

Q 01 FDNY Exam Newest /Q 01 FDNY Exam Preparation/Q 01 FDNY Practice Exam With Complete Questions And Correct Detailed Answers (Verified Answers) |Already Graded A+|Brand New Version!!

Institution
Q 01 FDNY
Course
Q 01 FDNY

Content preview

Q-01 FDNY Exam Newest /Q-01 FDNY Exam
Preparation/Q-01 FDNY Practice Exam With Complete
Questions And Correct Detailed Answers (Verified
Answers) |Already Graded A+|Brand New Version!!
Which of the following statements is incorrect?
A) A service valve is a key-operated shut-off valve used during shipment,
installation and repairs
B) Brine is a liquid cooled by refrigeration and used for the transmission of heat
C) A fusible plug has a set-temperature fusible member to relieve pressure
D) A rupture member automatically ruptures at a predetermined temperature -
ans -D) A rupture member automatically ruptures at a predetermined
temperature

Oil in a refrigerant should
A) have a high pour point
B) have a low flash point
C) have a high viscosity
D) not contain moisture - ans -D) not contain moisture

In an NH3 dry expansion evaporator with TXV and bulb clamped properly on the
outlet of the evaporator, the superheat is
A) 7 to 10° F
B) 5 to 9° F
C) 20 to 30° F
D) 1 to 2° F - ans -A) 7 to 10° F

The setting of a fusible plug is
A) 280° F
B) 300° F
C) 380° F
D) 300 psig. - ans -A) 280° F

If the insulation was removed from the bulb of the expansion valve, what would
happen? - ans -Flooded evaporator —the TXV bulb opens in a range from 45 to

,85° F. If the insulation was removed, the bulb would sense the temperature in the
machine room and keep the TXV open, thus flooding the evaporator.

On the most common three-phase, four-wire service, the voltage between any
phase and neutral should be
A) 105 volts
B) 120 volts
C) 208 volts
D) 220 volts - ans -B) 120 volts

A refrigerant overcharge would
A) increase head pressure
B) decrease head pressure
C) decrease solution-side pressure
D) decrease discharge-side pressure - ans -A) increase head pressure

A dryer is generally installed with other equipment in a commercial Freon
compressor system. The recommended location of this dryer is on the
A) high-pressure line between condenser and reciever
B) suction line between evaporator and compressor
C) discharge line between compressor and condenser
D) liquid line between receiver and expansion valve - ans -D) liquid line between
receiver and expansion valve

R-22 —What does it smell like? - ans -Odorless

Desirable characteristics of a refrigerant:
A) High __________
B) Low __________ - ans -A) High critical point
B) Low freezing point

Centrifugal Feed Water Pump
A) Start-up procedure
B) Shut-down procedure - ans -A) Start-up procedure
1) Lock-out, tag-out
2) Close discharge valve
3) Open suction valve

,4) Turn on
5) Open discharge valve
B) Shut-down procedure
1) Lock-out, tag-out
2) close suction valve
3) close discharge valve

In order to vary the capacity of an absorption plant, you should regulate the.. -
ans -Flow of the water to the condenser

600,000 btu per hour equals how many tons of refrigeration?
A) 300
B) 3,000
C) 500
D) 50 - ans -D) 50

Heat transfer takes place by
A) evaporation, conduction and condensation
B) radiation, conduction and convection
C) condensation, evaporation and radiation
D) sublimation, evaporation and convection - ans -B) radiation, conduction and
convection

Refrigerant recovery is defined as
A) Removing the refrigerant from a system and storing it in an external container,
with the lowest emissions possible.
B) Reprocessing a refrigerant into a new product that can be reused in another
system.
C) The process of cleaning a refrigerant of dirt and contaminates, such as oil, acid,
foreign material and non condensibles.
D) None of the above. - ans -A) Removing the refrigerant from a system and
storing it in an external container, with the lowest emissions possible.

A 10-ton refrigeration unit has a capacity of
A) 2,000 btu/minute
B) 12,000 btu/minute
C) 20,000 btu/minute

, D) 144,000 btu/day - ans -A) 2,000 btu/minute

In an absorption system, the medium normally used to vaporize refrigerant and
increase its temperature is
A) water
B) propane
C) ethylene
D) steam - ans -D) steam

Any water present in the refrigerant side of a Freon refrigerating system causes a
A) clogged oil trap
B) frozen discharge valve
C) clogged scale trap
D) frozen expansion valve - ans -D) frozen expansion valve

The subcooling effect of the liquid refrigerant just before the expansion valve
causes increased
A) horsepower
B) refrigeration effect
C) expansion valve capacity
D) refrigerant flow - ans -B) refrigeration effect

In a flooded evaporator using an accumulator and float valve, flash gas
A) passes directly into the evaporator
B) passes directly into the suction line
C) does not occur
D) stays in the receiver - ans -B) passes directly into the suction line

According to Title 49 CFR Section 173.34(e), cylinders and tanks must be
hydrostatically retested
A) once a year by visual inspection
B) a minimum of every 5 years
C) every six months
D) a minimum of once every 2 years - ans -B) a minimum of every 5 years

Written for

Institution
Q 01 FDNY
Course
Q 01 FDNY

Document information

Uploaded on
January 6, 2026
Number of pages
31
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Essiekarimi walden
View profile
Follow You need to be logged in order to follow users or courses
Sold
23
Member since
1 year
Number of followers
2
Documents
901
Last sold
13 hours ago
EXAM ESSENTIALS.

Welcome to your one-stop study hub! Where you Ace your exams with real exam past exams and high quality exam packs. Here you will find : >High quality' A graded study materials that have helped countless students succeed. > Comprehensive exam packs by topic eg pharmacology, Anatomy etc. >Instant downloads for quick and easy prep-anytime and anywhere. >High distinction study guides with answers. SAVE TIME, REDUCE ANXIEXTY AND REVISE WITH CONFIDENCE.

Read more Read less
4.0

4 reviews

5
3
4
0
3
0
2
0
1
1

Trending documents

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions