NFPA 160 Practice (NEW UPDATED VERSION) LATEST ACTUAL EXAM
QUESTIONS AND CORRECT ANSWERS (VERIFIED QUESTIONS AND ANSWERS) |
GUARANTEED PASS A+ UPDATED 2026-2027
1.
What is the primary purpose of NFPA 160?
A. To regulate fireworks sales
B. To establish fire investigation procedures
C. To provide safety requirements for flame effects before a proximate audience
D. To govern building sprinkler systems
Answer: C
Rationale: NFPA 160 focuses on flame effects safety in entertainment environments.
2.
A “proximate audience” is defined as an audience located:
A. Behind fire barriers
B. Outdoors only
C. In close proximity to flame effects
D. At least 50 feet away
Answer: C
Rationale: NFPA 160 applies when audiences are close enough to be exposed to flame effects.
3.
Who is responsible for ensuring compliance with NFPA 160 at an event?
A. The audience
B. The authority having jurisdiction (AHJ)
C. The flame effect operator
D. The equipment manufacturer
Answer: C
Rationale: The flame effect operator holds responsibility for safe operation and compliance.
2026 2027 GRADED A+
,2|Page
4.
Which document must be submitted to the AHJ before operating flame effects?
A. Insurance policy
B. Flame effects plan
C. Building permit
D. Material safety data sheet
Answer: B
Rationale: A detailed flame effects plan is required for approval.
5.
Which fuel type is most commonly regulated under NFPA 160?
A. Solid fuels
B. Liquid fuels
C. Gaseous fuels
D. Electrical ignition only
Answer: C
Rationale: Gaseous fuels such as propane are commonly used in flame effects.
6.
Which safety feature prevents uncontrolled fuel release?
A. Manual ignition
B. Emergency shutoff valve
C. Decorative housing
D. Audience barriers
Answer: B
Rationale: Emergency shutoff valves allow immediate fuel flow interruption.
7.
What is the minimum requirement for an emergency shutdown system?
A. Operated only by fire department
B. Automatically resets after use
C. Immediately stops fuel flow
D. Requires two operators
2026 2027 GRADED A+
, 3|Page
Answer: C
Rationale: Emergency systems must instantly stop fuel supply.
8.
Which component initiates the flame effect?
A. Fuel regulator
B. Ignition source
C. Ventilation system
D. Control panel
Answer: B
Rationale: Ignition sources initiate combustion.
9.
Flame effects equipment must be inspected:
A. Monthly
B. Annually
C. Before each use
D. Only after malfunction
Answer: C
Rationale: Pre-use inspection is mandatory for safety.
10.
Which condition would require immediate shutdown of flame effects?
A. Audience applause
B. Unexpected wind changes
C. Low fuel levels
D. Dim lighting
Answer: B
Rationale: Environmental changes can cause flame deflection and hazards.
2026 2027 GRADED A+