What action should be taken?
A. The sterilization time should be increased and the test rerun per manufacturer's IFU
B. CST should go ahead and load the sterilizer for sterilization to begin.
C. Sterilizer must be taken out of service until the issue is identified and fixed. - ANSWER-C.
Sterilizer must be taken out of service until the issue is identified and fixed.
QUESTION: The spore producing microorganism used in steam sterilizer testing is
A. Geobacillus Stearothermophilus
B. Bacillus Subtillus
C. Bacillus Atrophaeus - ANSWER-A. Geobacillus Stearothermophilus
QUESTION: Which of the following is used to reduce the amount of chloride in water that will
otherwise inhibit the effectiveness of deionization and reverse osmosis systems?
A. Descalers
B. Granular Activated Charcoal
C. Enzymatic detergent
D. Chelating Agents - ANSWER-B. Granular Activated Charcoal
QUESTION: Wha tis the packaging of choice for dry heat sterilization?
A. Aluminum Foil
B. Nonwoven wrap
C. Paper-plastic - ANSWER-A. Aluminum Foil
QUESTION: All of the following PPE are required by OSHA for techs in Decon except
A. Utility Gloves
,B. Face Protection
C. Shoe Covers
D. Scrub Attire - ANSWER-D. Scrub Attire
QUESTION: Which of the orgs work to prevent HAI. (Hospital Associated Infection)
A. ANSI
B. NFPA
C. APIC
D. USP-NF - ANSWER-C. APIC
QUESTION: Which of the following agencies develops recommended standards, practices and
guidelines for care and processing of devices?
A. DOT
B. FDA
C. SGNA
D. AAMI - ANSWER-D. AAMI
QUESTION: Which of the following sterilants will be most appropriate for point of use, just in
time processing system?
A. Peracetic Acid
B. Ethylene Oxide
C. Steam - ANSWER-A. Peracetic Acid
QUESTION: The length of time after which the efficiency of a disinfectant is diminished
A. Sterility
B. Shelf life
C. Effective period
D. Use Life - ANSWER-D. Use Life
QUESTION: The medical abbreviation ESS involves
A. Hip joint reconstruction
B. Treatment of fractured bone without with surgical incision.
C. Use of endoscopic instrumentation to operate on the nose. - ANSWER-C. Use of endoscopic
instrumentation to operate on the nose.
, QUESTION: The main objectives for tracking patient care equipment include all of the
following except
A. Provide information on trends
B. Provide information on current location
C. To track productivity - ANSWER-C. To track productivity
QUESTION: What is orchiopexy?
A. Making an opening onto the skull bone access the brain.
B. Straightening or removal of bone from the nose.
C. Relocating a non-descended testicle to the correct location in the scrotum. - ANSWER-C.
Relocating a non-descended testicle to the correct location in the scrotum.
QUESTION: Sterile packs should be stored ______ away from the exterior walls and windows
in the storage area
A. 8"
B. 1"
C. 2" - ANSWER-C. 2"
QUESTION: After sterilization, the wrapped package must cool to ____________
A. Body temperature
B. Room temperature
C. Temperatures below 50 degrees F. - ANSWER-B. Room temperature
QUESTION: Every load that contains implantable device must be monitored with
A. A minimum physical monitors
B. Process Challenge Device (PCD)
C. At a minimum a Chemical Indicator (CI) - ANSWER-B. Process Challenge Device (PCD)
QUESTION: The following agencies recognize that sterility is event related
A. The Joint Commission and AORN
B. AAMI and OSHA
C. AORN and OSHA - ANSWER-A. The Joint Commission and AORN
QUESTION: The relative humidity in the sterile storage area should be
, A. Less than 80%
B. Less than 70%
D. Between 30% and 75% - ANSWER-B. Less than 70%
QUESTION: What action should be taken if a failed BI is obtained after the release of processed
medical devices?
A. All medical devices processed in that sterilizer since the last negative biological indicator was
obtained must be recalled.
B. The medical devices must be recalled and reprocessed immediately.
C. The medical devices can only be used after the event is reported and documented. -
ANSWER-A. All medical devices processed in that sterilizer since the last negative biological
indicator was obtained must be recalled.
QUESTION: Which microorganism is used in the Biological indicator for monitoring Ethylene
Oxide (EtO)?
A. Bacillus Atrophaeus
B. Bacillus Subtilis
C. Staphylococcus aureus - ANSWER-A. Bacillus Atrophaeus
QUESTION: Spunbond-Meltdown-Spunbond packaging material should be used in which of
the following?
A. Steam Sterilizer
B. Gas Plasma
C. Ethylene Oxide - ANSWER-B. Gas Plasma
QUESTION: Which of the following is a requirement of the OSHA Bloodborne Pathogen
Standard?
A. Provide hepatitis B vaccine to employees
B. Keep biohazards areas locked
C. Provide body fluid resistant gowns - ANSWER-A. Provide hepatitis B vaccine to employees
QUESTION: After loaner instruments have been sterilized they should be
A. Kept in a cold room to effect rapid cooling
B. Moved to an area with low traffic to cool away
C. Immediately sent to the OR - ANSWER-B. Moved to an area with low traffic to cool away