Content preview

EPA Section 608 Type III Certification
Exam With Actual Questions & Verified
Answers, Plus Explained
Rationales/Expert Verified For
Guaranteed Pass 2026/Latest
Updated/Instant Download Pdf

1. What type of refrigerants are primarily handled under Type III
certification?
A. High-pressure refrigerants
B. Low-pressure refrigerants
C. Very high-pressure refrigerants
D. All types of refrigerants
B. Low-pressure refrigerants
Type III certification covers low-pressure refrigerants, typically those
with a saturation pressure below 45 psia at 104°F, commonly used in
chillers.
2. Which refrigerant is an example of a low-pressure refrigerant?
A. R-134a
B. R-22
C. R-123
D. R-410A

,C. R-123
R-123 is a low-pressure refrigerant commonly used in large chillers,
making it relevant for Type III certification.
3. The pressure in a low-pressure system is measured in psig. What
is the maximum typical operating pressure for Type III systems?
A. 15 psig
B. 30 psig
C. 45 psig
D. 60 psig
C. 45 psig
Type III systems are defined as low-pressure, operating below 45 psig at
104°F.
4. Which tool is essential for checking leaks in low-pressure
systems?
A. Nitrogen regulator
B. Ultrasonic leak detector
C. Low-pressure manifold gauge set
D. Combustion analyzer
C. Low-pressure manifold gauge set
Type III systems require specialized low-pressure gauges to safely
measure operating pressures.
5. When recovering refrigerant from a Type III system, which
practice is correct?
A. Recover only to 0 psig
B. Recover to 10 inches of Hg vacuum
C. Recover as much as possible without exceeding safe vacuum
levels
D. Open the system to the atmosphere after partial recovery

,C. Recover as much as possible without exceeding safe vacuum levels
EPA regulations require maximum recovery without risking system
damage or refrigerant loss.
6. Why is it important to avoid high vacuum during recovery on low-
pressure systems?
A. It causes condensation of refrigerant
B. It can damage the compressor
C. It can freeze water in the system
D. All of the above
D. All of the above
Excessive vacuum can cause moisture to freeze, damage compressors,
and affect proper refrigerant recovery.
7. What type of equipment is prohibited when handling Type III
refrigerants?
A. Refrigerant recovery units designed for low-pressure
B. Hand pumps
C. Recovery units certified for high-pressure only
D. Vacuum pumps rated for low-pressure
C. Recovery units certified for high-pressure only
High-pressure equipment may not safely recover low-pressure
refrigerants, and using it violates EPA regulations.
8. Which refrigerant is considered both low-pressure and mildly
flammable?
A. R-123
B. R-134a
C. R-1233zd
D. R-410A

, C. R-1233zd
R-1233zd is a low-pressure, mildly flammable HFO used in chiller
systems.
9. EPA Type III certification is required for technicians servicing
which systems?
A. Domestic refrigerators
B. Window AC units
C. Industrial chillers
D. Residential heat pumps
C. Industrial chillers
Type III certification is specifically for low-pressure systems found in
industrial chillers.
10. When performing a repair on a Type III system, which PPE is
required?
A. None
B. Safety glasses and gloves
C. Respirator only
D. Fire-resistant suit
B. Safety glasses and gloves
EPA requires basic PPE to prevent exposure to refrigerants and system
oils.
11. What is the correct method to charge a low-pressure
system?
A. Liquid refrigerant into the high side
B. Gas refrigerant into the suction side
C. Liquid refrigerant into the low side
D. Any method is acceptable

Written for

Institution
EPA Section 608 Type III Certification
Course
EPA Section 608 Type III Certification

Document information

Uploaded on
December 30, 2025
Number of pages
32
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

$21.99
Get access to the full document:

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
DrNotionNova Teachme2-tutor
View profile
Follow You need to be logged in order to follow users or courses
Sold
91
Member since
10 months
Number of followers
1
Documents
9687
Last sold
6 days ago
Top Grade Tutoring

Welcome to TOP GRADE Tutoring– your trusted source for accurate, reliable, and up-to-date study materials. As a certified tutor, I understand how important the right resources are for exam preparation and academic success. That’s why every guide, test bank, and study package in this shop is carefully curated, professionally organized, and designed to help you succeed. Here, you’ll find: • Comprehensive Guide to U.S. Certification & Licensing Exams • All-in-One Directory of U.S. Professional Certification Exams • United States Certification & Licensing Exams Master List • National Certification Exams Index: All U.S. Professions • Complete U.S. Credentialing & Certification Exam Catalog Specialized Nursing Exam Resources: • Up-to-date exams and assignments • Detailed test banks with verified questions and answers • Elaborate exam solutions • Case studies and discussion-based content Customized package deals are available to suit your specific needs. I am committed to delivering only top-tier documents to ensure the best outcomes for your academic success. Gain instant access to expertly curated materials designed to help you excel in your studies and certifications. Reach out today and take the next step toward achieving your academic and professional goals! Feedback is always welcome. I encourage all clients to leave a review after purchase—whether positive or constructive—to help me improve and continue offering the best possible support.

Read more Read less
3.8

17 reviews

5
8
4
2
3
4
2
2
1
1

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions