Edition Actual Complete Real Exam Questions with verified
Answers (100% Correct Answers) Already Graded A+ |
Guaranteed Success!! | Newest Exam | Just Released !!
According to ASME B30.3 and OSHA you should always
have at least how
many. wraps on a hoist drum - ANSWER-2 ASME 3-
3.2.1(d)(7)
What is the minimum allowable distance from the crane and
power lines under
50kV - ANSWER-10ft 3-
3.4.3(1)
According to ASME B30.3, how many randomly broken wires
must there be to
remove a running wire rope from serivce - ANSWER-12 ASME
3-3.4.3(b)(1)
According to ASME B30.3 when working near power lines when
is a signal person required - ANSWER-When crane moves
within a booms length of power lines ASME 3-3.4.3(a)(3)
,According to OSHA after the crane has been checked out and
before personnel lift operations begin the crew should -
ANSWER-Have a pre-lift meeting OSHA 1926.550(g)(8)
According to OSHA when is it safe to work closer than the
allowable distance
from the power lines - ANSWER-When utility company
says lines are de-
energized OSHA
1926.550(a)(15)(vi)
When should a tagline be used - ANSWER-When rotation of
load would be
dangerous ASME 3-
3.2.1(d)(8)
What is the minimum design factor required for a boom hoist
rope - ANSWER-
3.55 ASME 3-
1.5.5(c)
How many broken wires must be present in one stand on one
lay for running
wire rope to be removed from service - ANSWER-4 ASME
3-2.4.3(b)(1)
What is the maximum permitted wind speed when climbing a
tower - ANSWER-
, 20mph ASME 3-
1.1.5(i)
According to ASME B30.3 a crane should be plumbed to -
ANSWER-1 to 500
ASME 3-
1.1.5(g)
According to ASME B30.3 the rated load under static conditions
shall not exceed __________________ of calculated tipping
loads - ANSWER-63%
ASME 3-1.2.1(a)
According to ASME B30.3 an overhead power line is ALWAYS
considered to be - ANSWER-Energized until the power
company has verified it is not energized
High Tensile bolts should be marked with manufacturers
designation and -
ANSWER-Strength rating TCCM
Bolting 4-4
Bolt connections for tower sections must use high tensile
strength nuts with
ratings of - ANSWER-12 TCCM
Bolting 4-5
Washers used in high tensile bolt connections shall be marked
with - ANSWER-