To accurately measure liquid level in a closed tank under pressure, use a:

A. Bubbletube

B. Diaphragm box

C. Float cable

D .Dp transmitter - ANSWER-D .Dp transmitter



OSHA requires that existing conditions be tested or inspected before beginning work on electrical
equipment by using a:

A. Multimeter

B. Voltage calibrator

C. Megger

D . Amp probe - ANSWER-A. Multimeter



Weight is defined as:

A. The amount of matter in an object

B. The force exerted by a mass due to gravity

C .How much mass a body has

D. The rate at which a mass is accelerated - ANSWER-B. The force exerted by a mass due to gravity



Deadband in a switch refers to the:

A. A range of process changes before switch actuation

B. Range of setpoint repeatability

C. Allowable overshoot of a set point

D. Range of process change between actuation point and reset - ANSWER-A. A range of process changes
before switch actuation

,The adjustment that allows pressure contacts to reset is called the:

A. Set point

B. Reset point

C .Deadband

D. Operating range - ANSWER-B. Reset point



The value of the dynamic variable desired in a process is the:

A. Signal

B . Setpoint

C. Resolution

D. Specific gravity - ANSWER-B . Setpoint



A nuclear measuring device is typically used to measure:

A . Level

B. Temperature

C. Pressure

D. pH - ANSWER-A . Level



What does a solenoid valve do?

A. Opens and closes valves

B. Serves as a actuator to open and close pneumatic and hydraulic valves

C.Transforms volts to millivolts

D. Actuates to open and close terminal blocks - ANSWER-B. Serves as a actuator to open and close
pneumatic and hydraulic valves



What is the psi reading on MOST gauge pressure indicators at atmospheric pressure ?

A. 100

B. 10

C. Zero

,D. Below zero - ANSWER-C. Zero



Proportional control is also known as:

A. Derivative control

B. Reset control

C. Gain control

D. On-off control - ANSWER-A. Derivative control



The documentation required ot loop check and commission are:

A. P&ID, loop diagrams, and instrument specification sheets

B. P&ID and electrical drawings

C. Electrical drawings and typical installation detail sheets

D. Logic diagrams, loop sheets, and instrument operation manuals - ANSWER-A. P&ID, loop diagrams,
and instrument specification sheets



In an instrument loop, where would wet instrument air show up first?

A. In the air piping

B . At the dryer

C .In the filter regulator

D. At the valve positioner - ANSWER-B . At the dryer



Bills of materials are found in:

A .General arrangement drawings

B. Instrument detail drawings

C. Piping orthographics

D. P&ID - ANSWER-A .General arrangement drawings



Signal cable shields should be connected to ground at:

A . 1 point in the signal path

, B. Each accessible point in the signal path

C. Each end of the signal path

D. Each junction point in the signal path - ANSWER-A . 1 point in the signal path



Where would an instrument fitter find a P&ID

number for a particular instrument?

A. In the instrument installation details

B. On pipe drawings

C. In an instrument index

D. On the instrument location drawing - ANSWER-C. In an instrument index



To measure level, which variable is critical for accurate measurement?

A. Specific Gravity

B. Pressure

C. Temperature

D. Flow - ANSWER-A. Specific Gravity



The ASMT factors affection required wall thickness of tubing include al of the following EXCEPT:

A .Working pressure

B. Working temperature

C. Support type

D. Material type - ANSWER-C. Support type



What instrument drawing shows an actual representation of a process operating sequence?

A .Orthographic drawing

B. Location drawing C .Isometric drawing

D. P&ID - ANSWER-D. P&ID



The three basic types of fluid flow are laminar flow, turbulent flow, and:

Document information

Uploaded on
December 18, 2025
Number of pages
44
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$28.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
QUIZSOLUTIONS
3.0
(1)
Sold
13
Followers
5
Items
953
Last sold
11 months ago


Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions