Cross bridging on floor joists:
a. Stops floor squeaks
b. Removes sags from sub flooring
c. Keeps joists from twisting
d. Serves no purpose
Give this one a try later!
Keeps joists from twisting
If natural gas line is changed to LP, you need:
a. Smaller orifice
b. Larger orifice
c. To change valve assembly
d. Do nothing
,Give this one a try later!
Smaller orifice
A furnace has a pilot, thermocouple setup. What shuts down the burner:
a. Thermocouple
b. Pilot
c. Gas valve
d. Burners
Give this one a try later!
Thermocouple
Moisture accumulates in poorly vented attic because:
a. Moisture rises
b. Moisture attracted to cold
c. Warm air rises & condenses in the attic
d. All of the above
Give this one a try later!
Warm air rises & condenses in the attic
The insulation vapor barrier should face toward the heated side (living space) of the
insulation because:
a. Moisture could condense in the insulation if the vapor barrier faces the cold side.
,b. The vapor barrier will deteriorate if exposed to extreme cold
c. The vapor barrier facing can be a fire hazard if exposed on the attic side
d. The insulation must 'breathe' the same air as the unconditioned space
Give this one a try later!
Moisture could condense in the insulation if the vapor barrier faces the
cold side.
Gas water heaters are allowed in all of the following locations except:
a. Basements accessible only from interior stairs
b. Attics accessible only from a permanent ladder
c. Storage closets
d. Laundry rooms open to the living area
Give this one a try later!
Storage closets
The two main components of an air-cooled air conditioning system are:
a. The fan & coil
b. Duct work and the expansion unit
c. Evaporator unit and the condenser unit
d. Compressor and refrigerant
Give this one a try later!
, Evaporator unit and the condenser unit
Moisture trapped under a BUR will cause:
a. Blistering
b. Alligatoring
c. No consequence
d. Additional insulation value
Give this one a try later!
Blistering
What is the sign of a cracked heat exchanger:
a. Dirty burners
b. Flame distortion
c. Dirty registers
d. Poor pilot performance
Give this one a try later!
Flame distortion
Refer to Fig. 11, how would you report:
a. Say nothing
b.Ok
c. Fused neutral - safety issue
d. Ok for sub panel only
a. Stops floor squeaks
b. Removes sags from sub flooring
c. Keeps joists from twisting
d. Serves no purpose
Give this one a try later!
Keeps joists from twisting
If natural gas line is changed to LP, you need:
a. Smaller orifice
b. Larger orifice
c. To change valve assembly
d. Do nothing
,Give this one a try later!
Smaller orifice
A furnace has a pilot, thermocouple setup. What shuts down the burner:
a. Thermocouple
b. Pilot
c. Gas valve
d. Burners
Give this one a try later!
Thermocouple
Moisture accumulates in poorly vented attic because:
a. Moisture rises
b. Moisture attracted to cold
c. Warm air rises & condenses in the attic
d. All of the above
Give this one a try later!
Warm air rises & condenses in the attic
The insulation vapor barrier should face toward the heated side (living space) of the
insulation because:
a. Moisture could condense in the insulation if the vapor barrier faces the cold side.
,b. The vapor barrier will deteriorate if exposed to extreme cold
c. The vapor barrier facing can be a fire hazard if exposed on the attic side
d. The insulation must 'breathe' the same air as the unconditioned space
Give this one a try later!
Moisture could condense in the insulation if the vapor barrier faces the
cold side.
Gas water heaters are allowed in all of the following locations except:
a. Basements accessible only from interior stairs
b. Attics accessible only from a permanent ladder
c. Storage closets
d. Laundry rooms open to the living area
Give this one a try later!
Storage closets
The two main components of an air-cooled air conditioning system are:
a. The fan & coil
b. Duct work and the expansion unit
c. Evaporator unit and the condenser unit
d. Compressor and refrigerant
Give this one a try later!
, Evaporator unit and the condenser unit
Moisture trapped under a BUR will cause:
a. Blistering
b. Alligatoring
c. No consequence
d. Additional insulation value
Give this one a try later!
Blistering
What is the sign of a cracked heat exchanger:
a. Dirty burners
b. Flame distortion
c. Dirty registers
d. Poor pilot performance
Give this one a try later!
Flame distortion
Refer to Fig. 11, how would you report:
a. Say nothing
b.Ok
c. Fused neutral - safety issue
d. Ok for sub panel only