2026/l 2027l Update) 100%l Verifiedl
Questionsl &l Answersl |l Gradel A
Q:l Inl anl electricall system,l whatl isl thel whitel wire?
1.l hot
2.l neutral
3.l ground
4.l jumper
Answer:
B.l Thel whitel wirel isl thel "neutral"l wire,l itl takesl anyl unusedl electricityl andl currentl andl
sendsl itl backl tol thel breakerl panel.
Q:l Whatl isl printedl onl thel labell ofl undergroundl direct-buriall wire?
1.l UG
2.l LL
3.l UF
4.l UL
Answer:
C.l Referencel 2022l CECl 340.6l Listingl Requirements.l Typel UFl cablel andl associatedl
fittingsl shalll bel listed.
Q:l Whenl outdoorl ratedl fiberl cablel entersl al building,l itl shouldl bel splicedl tol anl
indoor-typel fiberl cablel withinl ________l froml thel cablel entrance.
1.l 25l feet
2.l 30l feet
3.l 40l feet
4.l 50l feet
Answer:
D.l
Q:l Whichl ofl thel followingl mustl bel postedl atl alll jobl sites?
1.l Earthquakel Preparedness
,2.l Firstl Aidl Kit
3.l Firel Escapel Routel Map
4.l Alll ofl these
Answer:
B.l Referencel thel Californial Codel ofl Regulations,l Titlel 8,l Sectionl 1512(c)l First-Aidl Kit.l
(1)l Everyl employerl workingl onl orl furnishingl personnell onl al constructionl project,l onl
linel crewsl andl onl otherl shortl durationl orl transientl jobsl shalll providel atl leastl onel first-
aidl kitl inl al weatherproofl container.l Thel contentsl ofl thel first-aidl kitl shalll bel inspectedl
regularlyl tol ensurel thatl thel expendedl itemsl arel promptlyl replaced.l Thel contentsl ofl thel
first-aidl kitl shalll bel arrangedl tol bel quicklyl foundl andl remainl sanitary.l First-aidl
dressingsl shalll bel sterilel inl individuallyl sealedl packagesl forl eachl item.
Q:l Whatl isl thel purposel ofl AFCIs?
1.l tol protectl againstl electricl shocks
2.l tol protectl againstl powerl outages
3.l tol protectl againstl fires
4.l tol protectl againstl metall thieves
Answer:
C.l AFCIl standsl forl Arc-Faultl Circuitl Interrupter.l Theyl arel similarl tol GFCIsl butl theyl
protectl againstl housel firesl causedl byl arcing.l Arcingl canl bel causedl byl manyl things,l
includingl deteriorationl ofl oldl wiring,l damagel tol wiringl causedl byl nailsl orl staples,l
damagedl cordsl ofl cord-and-plugl connectedl equipmentl (lamps,l alarml clocks,l etc.),l orl
havingl furniturel pushedl upl againstl anl outletl andl dislodgingl al plug.l Itl isl possiblel forl
anl arcl tol startl al firel eitherl inl thel furnishingsl ofl thel rooml orl insidel thel walll cavity.l
Thel AFCIl isl intendedl tol sensel thel arcingl andl de-energizel thel circuit.l Itl isl
acknowledgedl thatl AFCIsl cannotl preventl alll electricall firesl sincel thel devicel willl notl
tripl untill afterl arcingl hasl beenl sensedl andl thel firstl arcl mayl ignitel al fire.l Thel riskl ofl
firel isl greatlyl reduced,l however,l becausel thel AFCIl willl preventl subsequentl arcingl inl
thel casesl wherel thel firstl arcl doesl NOTl ignitel al fire.
Q:l Anl ICl contains:
1.l Diodes
2.l Resistors
3.l Transistors
4.l alll ofl these
Answer:
,D.l Anl integratedl circuitl (IC),l sometimesl calledl al chip,l microchipl orl microelectronicl
circuit,l isl al semiconductorl waferl onl whichl thousandsl orl millionsl ofl tinyl resistors,l
capacitors,l diodesl andl transistorsl arel fabricated.
Q:l Thel "555"l ICl isl a?
1.l Amplifierl circuit
2.l ANDl circuit
3.l Timerl circuit
4.l Powerl supplyl circuit
Answer:
C.l Answerl "C"l isl correct.l Thel 555l timerl ICl isl anl integratedl circuitl usedl inl al varietyl
ofl timer,l delay,l pulsel generation,l andl oscillatorl applications.
Q:l Howl manyl wiresl wouldl youl runl froml thel controller,l ifl youl havel al six-l stationl
Sprinklerl station?
1.l 8
2.l 7
3.l 9
4.l 6
Answer:
B.l 6l +l 1l common.l Youl havel thel 6l controllerl wiresl andl thel onel commonl wirel whichl
isl thel groundl wire.
Q:l Exteriorl connectorsl usedl onl conduitl are:
1.l waterproof
2.l water-resistant
3.l eitherl water-resistantl orl waterproof
4.l galvanized
Answer:
C.l Connectorsl suitablel forl outsidel installationsl arel notl alll waterproof.l Connectorsl arel
selectedl basedl onl theirl ULl listingl forl al specificl purpose.l Outsidel connectorsl shouldl bel
atl leastl raintight,l butl ifl thel installationl isl belowl gradel orl subjectl tol immersion,l thisl isl
notl enough.l Plasticl orl aluminuml connectorsl arel notl galvanized.
Q:l Whatl typel mustl low-voltagel controll conductorsl be?
1.l LL
, 2.l UF
3.l UG
4.l UL
Answer:
B.l UFl conductorsl arel undergroundl feederl cablesl thatl arel usedl inl al varietyl ofl
applications,l including:l Irrigation:l UFl cablesl arel usedl inl thel irrigationl industryl tol
providel powerl tol submersiblel pumpsl andl irrigationl systems.l Theyl canl bel buriedl
directlyl undergroundl orl usedl inl al raceway.l Sheds:l UFl cablesl arel oftenl usedl tol runl
electricityl tol al sub-panell inl al shed.
Interiorl wiring:l UF-Bl cablesl canl bel usedl forl interiorl branchl circuitl wiringl inl residentiall
orl agriculturall buildings.
Q:l Thel thermostatl forl al H.V.A.C.l system,l shouldl bel mountedl howl manyl feetl froml
thel floor?
1.l 6l feet
2.l 5l feet
3.l 4l feet
4.l 3l feet
Answer:
C.l 2019l Californial Energyl Codel listsl followingl thel thermostatl manufacturer'sl
recommendationl perl 2019l Californial Energyl Code,l sectionl 110.2;l andl 2019l Californial
Accessibilityl Codel listsl 48l inchesl perl 1136A.2.
Q:l Al transistorl canl workl asl (a)an:
1.l Switch
2.l Inverter
3.l Amplifier
4.l alll ofl these
Answer:
D.l Thel transistorl willl operatel asl anl amplifierl orl otherl linearl circuitl ifl thel transistorl isl
biasedl intol thel linearl region.l Thel transistorl canl bel usedl asl al switchl ifl biasedl inl thel
saturationl andl cut-offl regions.l Al transistorl workl likel anl inverterl suchl asl producingl al
highl signall (logicl 1)l atl thel outputl whenl thel appliedl inputl isl low,l andl itl canl producel al
lowl signall (logicl 0)l atl thel outputl whenl thel appliedl inputl isl high.
Q:l Thel voltagel inl al low-voltagel gardenl lightsl is?
1.l 6V