MDCB 2025 FINAL EXAM QUESTIONS AND CORRECT ANSWERS (T/F) In SAD techniques, the beams are weighted at dmax point. - CORRECT ANSWERS False (T/F) In SAD techniques, the beams are weighted at target center. - CORRECT ANSWERS False (T/F) Isodose or PDD data can be used directly for a patient, without any modification. - CORRECT ANSWERS False (T/F) TAR concept is usually not used with accelerator photon beams because the dose in free air is not well defined due to conceptual difficulties - CORRECT ANSWERS (T/F) TAR can be measured directly or derived from the PDD data. - CORRECT ANSWERS True (T/F) In general TAR increases with increase in depth. - CORRECT ANSWERS True False (T/F) At orthovoltage beam quality's (about 0.5 mm Cu HVL) BSF increases with an increase in energy. - CORRECT ANSWERS False (T/F) TAR decreases with increase in field size. - CORRECT ANSWERS False (T/F) Exit dose calculated using the standard PDD tables would give the correct exit dose. - CORRECT ANSWERS False (T/F) The off axis ratio is the dose at any point in a plane perpendicular to the central axis to that of the dose on the central axis in that plane. - CORRECT ANSWERS True (T/F) At a phantom depth of 10 cm, on the central axis, scatter contribution to the dose is more for an accelerator photon beam compared to a Co-60 beam. - CORRECT ANSWERS False (T/F) At any depth, the scatter contribution to total dose decreases with increase in incident photon energy - CORRECT ANSWERS True (T/F) Cross-beam profile can give information regarding field size, physical penumbra, beam f latness, and symmetry. - CORRECT ANSWERS True

Content preview

MDCB 2025 FINAL EXAM QUESTIONS AND
CORRECT ANSWERS
(T/F) In SAD techniques, the beams are weighted at dmax point. - CORRECT
ANSWERS False



(T/F) In SAD techniques, the beams are weighted at target center. - CORRECT
ANSWERS False



(T/F) Isodose or PDD data can be used directly for a patient, without any modification. -
CORRECT ANSWERS False



(T/F) TAR concept is usually not used with accelerator photon beams because the dose in free
air is not well defined due to conceptual difficulties - CORRECT ANSWERS True



(T/F) TAR can be measured directly or derived from the PDD data. - CORRECT
ANSWERS True



(T/F) In general TAR increases with increase in depth. - CORRECT ANSWERS False



(T/F) At orthovoltage beam quality's (>about 0.5 mm Cu HVL) BSF increases with an increase in
energy. - CORRECT ANSWERS False



(T/F) TAR decreases with increase in field size. - CORRECT ANSWERS False



(T/F) Exit dose calculated using the standard PDD tables would give the correct exit dose. -
CORRECT ANSWERS False

,(T/F) The off axis ratio is the dose at any point in a plane perpendicular to the central axis to that
of the dose on the central axis in that plane. - CORRECT ANSWERS True



(T/F) At a phantom depth of 10 cm, on the central axis, scatter contribution to the dose is more
for an accelerator photon beam compared to a Co-60 beam. - CORRECT ANSWERS False



(T/F) At any depth, the scatter contribution to total dose decreases with increase in incident
photon energy - CORRECT ANSWERS True



(T/F) Cross-beam profile can give information regarding field size, physical penumbra, beam
flatness, and symmetry. - CORRECT ANSWERS True



(T/F) A wedge in motion is known as a dynamic wedge. - CORRECT ANSWERS False



(T/F) The energy fluence of the photons falls according to the inverse square law of distance
with the source position as the origin. - CORRECT ANSWERS True



(T/F) Photon beams have a finite range in a patient. - CORRECT ANSWERS False



(T/F) In the AAPM TG-51 protocol, the electron beam quality is specified by E0 , the mean
energy of the electrons incident on the patient. - CORRECT ANSWERS False



(T/F) The field size dependence of the PDD of an accelerator photon beam is very much
influenced by the electron contamination of the beam - CORRECT ANSWERS True



(T/F) Scatter generally decreases PDD. - CORRECT ANSWERS False

,(T/F) Half blocked tangential breast treatments can be easily accomplished with independent
jaw movements. - CORRECT ANSWERS True



(T/F) One of the advantages of a dynamic wedge over a physical wedge for treatment is that
there is no change in beam quality across the field size. - CORRECT ANSWERS True



(T/F) The tail of the electron beam depth dose distribution is due to some long-range electrons
in the beam. - CORRECT ANSWERS False



(T/F) Electron beams have a finite range in medium. - CORRECT ANSWERS True



(T/F) Low-energy electrons are more easily scattered compared to high-energy electrons. -
CORRECT ANSWERS True



The beam output (cGy/min) measured in air for a Co-60 unit increases with field size mainly due
to:

collimator scatter

room scatter

couch backscatter

chamber wall scatter - CORRECT ANSWERS collimator scatter



Disadvantages of using a physical wedge include:



hardening of the beam, which also depends on wedge thickness



difficulty in positioning the wedge reproducibly in the beam path

, attenuation of the beam and an increase in treatment time



inconvenience in handling heavy wedges - CORRECT ANSWERS hardening of the beam,
which also depends on wedge thickness

attenuation of the beam and an increase in treatment time

inconvenience in handling heavy wedges



In case of isocentric treatment, compared to constant SSD method:



set-up time decreases



set-up error decreases



treatment accuracy increases



overall time to treat a patient increases - CORRECT ANSWERS set-up time decreases

set-up error decreases

treatment accuracy increases



The TAR:



concept is usually not preferred with accelerator photon beams because the dose in free air is
not well defined for these beams



can be derived from PDD data

Document information

Uploaded on
December 16, 2025
Number of pages
240
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$40.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
VictorGrades
3.0
(2)
Sold
22
Followers
0
Items
1359
Last sold
22 hours ago


Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions