1. Which of the following best defines “fail-secure” lock behavior?
A. The lock remains unlocked when power is lost.
B. The lock remains locked when power is lost.
C. The lock triggers an alarm when power is lost.
D. The lock enters low-power mode when power is lost.

Answer: B
Rationale: Fail-secure means the door remains locked if power is cut,
preserving security.

2. Under fire-alarm tie-in requirements, which behavior is required of access-
controlled doors?
A. They must stay locked for at least 30 more seconds.
B. They must unlock immediately for egress.
C. They must trigger a local audible alarm.
D. They must switch to battery backup until fire control is restored.

Answer: B
Rationale: Fire codes require that on fire-alarm activation, electrically
locked doors unlock to allow safe egress.

3. A Wiegand reader cable run exceeds recommended distance. Which issue
is most likely to occur?
A. Power overload at the reader
B. Data corruption or read errors

,C. Magnetic interference
D. Overheating of the controller

Answer: B
Rationale: Wiegand protocol is susceptible to signal degradation over long
distances, leading to read errors.

4. What is the typical signal voltage for a Wiegand data line at the reader
end?
A. 5 VDC
B. 12 VDC
C. 24 VAC
D. 3.3 VDC

Answer: A
Rationale: Wiegand data lines typically operate at TTL-level 5 V for
reliable data transmission.

5. For a door with a magnetic lock rated at 600 lb holding force, which of the
following hardware is most appropriate?
A. A heavy-duty door closer only
B. A pair of standard hinges
C. A rated steel frame and heavy-duty reinforced door
D. A glass door without frame

Answer: C
Rationale: The holding force requires door and frame hardware rated to
resist forced entry.

6. What does “PoE” stand for in the context of IP-based access control
readers?
A. Power over Ethernet
B. Protocol over Ethernet
C. Power on Entry
D. Peripheral over Ethernet

,Answer: A
Rationale: PoE supplies power and data over the Ethernet cable,
simplifying IP-reader installation.

7. Which wiring gauge is generally recommended for power runs supplying
magnetic locks over moderate distances?
A. 22 AWG
B. 18 AWG
C. 14 AWG
D. 26 AWG

Answer: C
Rationale: 14 AWG reduces voltage drop over distance and supports the
current draw of magnetic locks.

8. In an access control database, what does “locks staging” refer to?
A. Scheduling a lock timing change
B. Temporarily bypassing the lock
C. Having the door pre-unlocked during an event
D. Programming multiple locks to react in a sequence

Answer: D
Rationale: Locks staging allows coordinated actions of multiple locks —
useful in lockdowns or sequential access flows.

9. Which device is most appropriate to detect door forced-open events for
audit logging?
A. Magnetic lock
B. Request-to-Exit (REX) button
C. Door position switch (DPS) or contact sensor
D. Keypad reader

Answer: C
Rationale: A DPS or contact sensor detects actual door position changes —
essential for forced-open or propped-door alarms.

10. For a door that must remain open during business hours but lock after
hours automatically, you would use:

, A. A standard key locksmith
B. A timed relay tied to controller schedule
C. A mechanical deadbolt
D. A motion-activated battery lock

Answer: B
Rationale: A timed relay allows lock behavior to follow schedule — locking
after hours automatically.

11. Which standard is commonly referenced for egress door hardware in
commercial buildings?
A. UL 294
B. NFPA 101 (Life Safety Code)
C. ANSI 300
D. IEEE 802.3

Answer: B
Rationale: NFPA 101 governs means of egress and exit hardware,
including requirements for access-controlled doors.

12. What feature distinguishes a “reader-in / reader-out” door from a
“reader-in only” door?
A. It has two different card formats.
B. It requires credential presentation both on entry and exit.
C. It uses biometric authentication.
D. It supports fire-alarm tie-in.

Answer: B
Rationale: “Reader-in / reader-out” enforces credential presentation in
both directions, improving security and audit trail.

13. What is the main advantage of “fail-safe“electromagnetic locks in
emergency exit scenarios?
A. They never require power.
B. They unlock instantly on power loss, aiding egress.
C. They lock more strongly when power resumes.
D. They use less power overall.

Document information

Uploaded on
December 7, 2025
Number of pages
31
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$23.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
TheExamWhisperer
3.9
(178)
Sold
969
Followers
14
Items
31025
Last sold
17 hours ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions