QUESTION: Which of the following can be programmed on an MMU to latch after a fault

occurs? - ANSWER-Field check




QUESTION: How often is an MMU's clock updated from the controller? - ANSWER-Once a

second




QUESTION: In a signal cabinet, on the signal monitor, what does a field check indicate? -

ANSWER-The signal indications don't match the controller output for a phase




QUESTION: A NEMA CMU/MMU uses a program card to tell the monitor which phases are

permitted to run together. Which answer is CORRECT? - ANSWER-NEMA monitors have wire

jumpers missing in all positions, the tech solders the ones in that allow phases to run together.




1

, Page 2 of 57




QUESTION: When the controller timings DO NOT match the timing sheet, who should be

contacted for correct


times? - ANSWER-Traffic Engineer




QUESTION: An older TS1 cabinet experiences a flash condition but the signal heads are also

showing active green, yellow, and red indications. What is the MOST COMMON issue? -

ANSWER-The mercury contactor is stuck in the normal position.




QUESTION: In a Dual-Ring, 8-phase traffic signal controller, how many phases can run in each

ring at the same


time? - ANSWER-1




QUESTION: Observations indicate that vehicles are being detected in one lane and that this is

shown on the detection interface unit. However, the controller does not show any detection for

that phase. This could be caused by - ANSWER-Improper detection phase assignment

programming in the controller




2

, Page 3 of 57


QUESTION: As soon as vehicles leave the detection zone of an approach that has met its

minimum green time, a signal immediately goes to yellow from the green display. This could be

a result of - ANSWER-no extension time programmed.




QUESTION: What is one reason the phase interval may change even though there is still vehicle

demand? - ANSWER-maximum green time has been met




QUESTION: A signal tech is reviewing the controller logs and continually sees a cycle fault error.

What does that


mean? - ANSWER-The CU has not serviced a call in two cycles while in free mode.




QUESTION: A coordinated corridor is working well except at one intersection where a platoon

of vehicles is being stopped. The MOST LIKELY problem is the - ANSWER-clock has drifted

affecting the offset and needs adjusting




QUESTION: Observations indicate that right turning vehicles approach the intersection on the

side street, stop and then make a right turn on red. When this happens the signals cycle to the




3

, Page 4 of 57


side street even though there are no longer vehicles present in the detection zone. This could

be caused by - ANSWER-the detection being set to locking detection




QUESTION: Of the following, which answer MOST LIKELY would require a controller database be

verified to be


correct? - ANSWER-When a controller upgrade has been performed




Q; In a TS2 cabinet, how many times can the MMU experience a "Port 1 Fail" in a 24 hour

period before


the fault is latched? - ANSWER-1




QUESTION: On a 2070 MMU monitor unit, how does the field tech program allowable phases? -

ANSWER-Remove diode on program card for allowable phases




QUESTION: On an MMU, is it possible to tape the reset button to prevent the traffic signal from

going into flash? - ANSWER-Yes, it by-passes the conflict feature and will not flash




4

Documentinformatie

Geüpload op
5 december 2025
Aantal pagina's
57
Geschreven in
2025/2026
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden
$23.49

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
STUVIAGRADES
4.7
(1068)
Verkocht
6657
Volgers
467
Items
9109
Laatst verkocht
1 dag geleden



Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen