Content preview

North Carolina Residential Single-Family
Dwelling Electrical Contractor Licensing Exam
Questions And Correct Answers (Verified
Answers) Plus Rationales 2026 Q&A | Instant
Download Pdf

QUESTIONS 1–50
1. The minimum service entrance rating for a new single-family
dwelling in North Carolina is:
A. 60 amps
B. 100 amps
C. 125 amps
D. 150 amps
Answer: B
100 amps is the NEC minimum for a dwelling unit service.


2. The minimum burial depth for a PVC Schedule 40 electrical conduit
under a residential driveway is:
A. 12 inches
B. 18 inches
C. 24 inches
D. 36 inches
Answer: C

,PVC under driveways must be at least 24 inches deep when not GFCI-
protected.


3. Receptacles in a residential garage must be protected by:
A. AFCI only
B. GFCI only
C. Both GFCI and AFCI
D. Neither
Answer: B
Garages require GFCI protection; AFCI is not required for garage
receptacles.


4. A 20-amp small appliance branch circuit must use conductors no
smaller than:
A. 16 AWG
B. 14 AWG
C. 12 AWG
D. 10 AWG
Answer: C
20-amp circuits require minimum 12 AWG copper.


5. The maximum allowable voltage drop for a branch circuit feeder to
ensure efficiency is recommended to be:
A. 3%
B. 5%

,C. 8%
D. 10%
Answer: A
NEC recommends 3% max on branch circuits for good performance.


6. The required minimum height for service drop conductors above a
residential walkway is:
A. 8 ft
B. 10 ft
C. 12 ft
D. 15 ft
Answer: B
Service drops must be at least 10 ft above pedestrian areas.


7. Kitchen countertop receptacles must be installed so that no point
along the wall line is more than how many feet from a receptacle?
A. 2 ft
B. 4 ft
C. 6 ft
D. 8 ft
Answer: B
Spacing requires no point more than 24 inches from a receptacle outlet.


8. A bathroom requires at least how many 20-amp branch circuits?

, A. None
B. One
C. Two
D. Three
Answer: B
Bathrooms require one 20-amp circuit for receptacles.


9. Smoke alarms must be on which type of circuit?
A. Dedicated
B. Multi-wire
C. AFCI-protected
D. GFCI-protected
Answer: C
Smoke alarms in dwelling units must be protected by AFCI.


10. The minimum working space depth in front of a 120/240-V
residential panelboard is:
A. 24 inches
B. 30 inches
C. 36 inches
D. 48 inches
Answer: C
36 inches is required for equipment 150 V to ground or less.


11. Receptacles in unfinished basements must be protected by:

Document information

Uploaded on
December 3, 2025
Number of pages
35
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$21.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Drprep
4.0
(152)
Sold
786
Followers
14
Items
19486
Last sold
14 hours ago

Reviews from verified buyers



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions