• Verkeerd document? Gratis ruilen
  • Geschreven door studenten die geslaagd zijn
  • Direct beschikbaar na je betaling
  • Online lezen of als PDF
Verkopen
Kies je studieland
Kies je taal
Document preview thumbnail
Voorbeeld 3 van de 24 pagina's
Tentamen (uitwerkingen)

MDCB Board Prep Exam Questions With 100- Verified Answers.docx

Document preview thumbnail
Voorbeeld 3 van de 24 pagina's

MDCB Board Prep Exam Questions With 100- Verified A

Voorbeeld van de inhoud

MDCB Board Prep Exam Questions
With 100% Verified Answers
The line focus principle is used in diagnostic x-ray tube design in
order to:
A. make the apparent anode smaller than the actual anode angle
B. make the apparent focal spot size smaller than the actual focal
spot size
C. make the apparent focal spot size larger than the actual focal
spot size
D. make the apparent anode angle smaller than the actual anode
angle -
correct answer ✅B. make the apparent focal spot size smaller than
the actual focal spot size


The apparent focal spot size equals the actual focal spot size x the
sin of the anode angle. This allows a larger portion of the anode to
be irradiated because the heat is more evenly dispersed, while
keeping the spatial resolution in the image as good as possible.


Insufficient vacuum inside the x-ray tube can lead to___________.
A. reducing image contrast
B. increased patient dose
C. tube arcing

,MDCB Board Prep Exam Questions
With 100% Verified Answers
D. need to increase tube voltage -
correct answer ✅C. tube arcing (no useful beam is produced when
the tube is arcing.


The output of an x-ray tube is approximately proportional to:
A. square of tube current at a given kVp
B. square of filament current at a given kVp
C. thickness of xray target
D. square of tube voltage at a given tube current -
correct answer ✅D. square of tube voltage at a given tube current


Output (kVp)^2 (mAs)


Standards defining the minimum necessary amount of inherent
filtration to be used in x-ray tubes are intended to ____________.
A. increase image contrast
B. reduce patient skin dose
C. increase x-ray tube life
D. allow reduced tube voltage -
correct answer ✅B. reduce patient skin dose

, MDCB Board Prep Exam Questions
With 100% Verified Answers
Filtration hardens the beam, increasing the portion of the beam
that penetrates the patient and contributes to the image. Increased
filtration reduces the image contrast.


The surface dose rate of Sr-90 eye applicator was 4.5 cGy/ second
on May 25. If a patient is to be treated 1 year later, what is the
treatment time if 500cGy is prescribed? (half life of Sr-90 is 28
years). -
correct answer ✅114 sec


When 10 mCi of I-125 (half life =60 days) and 25 mCi of Pd-103 (half
life = 17 years) have equal activities? -
correct answer ✅43.17 days


A 10 MeV photon undergoes a Compton interaction, and the
scattered photon is emitted perpendicular to the direction of the
incident photon. What is the approximate energy of the scattered
photon?
A. 0.51 MeV
B. 1.02 MeV
C. 1.25 MeV

Documentinformatie

Geüpload op
17 november 2025
Aantal pagina's
24
Geschreven in
2025/2026
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden
$15.99

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
Cindellera
4.0
(35)
Verkocht
205
Volgers
3
Items
16904
Laatst verkocht
6 dagen geleden




Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen