Surgical Technology Certification
2025/2026 EXAM ACTUAL EXAM
QUESTIONS AND WELL ELABORATED
ANSWERS WITH (100% VERIFIED
SOLUTIONS) LATEST
UPDATES | ALREADY GRADED A+


Which of the following is the correct temperature for pre-vacuum
sterilization? a. 212*F
b. 170*F
c. 300*F
d. 270*F - ANSWER>>ANSWER: D


Which of the following tests is specifically meant to test and monitor the
efficiency of the high - vacuum steam sterilizer? a. biological indicator
test
b. DART test
c. chemical indicator test
d. EtO test - ANSWER>>ANSWER:
B DART test = Bowie Dick test

,The surgical team must verify each package is properly labeled with a.
date of processing and method of sterilization
b. date of processing and indicator
c. method of sterilization and expiration date
d. indicator and expiration date - ANSWER>>ANSWER: B


How many times a day should a DART test be preformed? a.
with every load
b. every shift change
c. once every 24 hours
d. weekly - ANSWER>>ANSWER: C


How often must a biological control test be run? a.
every day
b. every cycle
c. once a week
d. once a month -
ANSWER>>ANSWER: A [pg. 163]


The Bowie-Dick test for pre-vacuum sterilizers checks for which of the
following conditions?
a. that the appropriate steam level was reached
b. air leaks in the sterilizer chamber
c. broken sterilizer jacket
d. that the sterilizer is ready to process instruments -
ANSWER>>ANSWER: B

,lot control numbers should be placed on each package sterilized and on
the...
a. sterilizer maintenance record
b. sterilization load record
c. nursing documentation
d. cover of the patient's chart - ANSWER>>ANSWER: B


How long is a 3M Attest 1292 steam biological indicator incubated before
the reading is recorded? a. 12 hours
b. 36 hours
c. 24 hours
d. 48 hours - ANSWER>>ANSWER:
C 12 hours - rapid ; 24 hours - not
rapid


During a vascular procedure a vessel is ligated. The surgeon states that
she will repair the vessel after bleeding is controlled. Which needle type
would she most likely require to complete this task? a. control release
needle
b. French eyed needle
c. tapered needle
d. cutting needle - ANSWER>>ANSWER: C

When steam sterilizing biological indicators, how long are they incubated
before the reading is recorded? a. 48 hours
b. 24 hours
c. 12 hours
d. 72 hours - ANSWER>>ANSWER: B

, An OB-GYN surgeon has posted a laparoscopic partial hysterectomy and
has informed the surgical team that the ovaries are remaining. However,
the fallopian tubes will require ligation involoving the tubes being clipped
and cauterized. Which of the following instruments should the surgical
technologist open
a. a Flishie and hemoclip applier
b. a Flishie and Kleppinger
c. a Kleppinger and harmonic scalpel
d. a harmonic scalpel and hemoclip applier - ANSWER>>ANSWER: D


Which of the following instruments can be decontaminated in the
washersterilizer?
a. colonoscope
b. power drill
c. laser coated instrument set
d. phaco instrument set - ANSWER>>ANSWER: C


The patient has undergone cardiac bypass surgery. Protamine has been
administered and the surgeon is preparing to close the sternotomy.

Bleeding is a postoperative concern. Which of the following systems should
the surgical technologist anticipate the surgeon will use? a. Hemovac
b. Jackson Pratt
c. Pleur-Evac
d. Penrose - ANSWER>>ANSWER: C

Escuela, estudio y materia

Institución
Surgical tech
Grado
Surgical tech

Información del documento

Subido en
10 de noviembre de 2025
Número de páginas
58
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

$12.99
Accede al documento completo:

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
AndrewBenson Johns Hopkins University
Ver perfil
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
23
Miembro desde
1 año
Número de seguidores
0
Documentos
1999
Última venta
1 mes hace

3.0

2 reseñas

5
1
4
0
3
0
2
0
1
1

Documentos populares

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes