Questions and Verified Answers
An oxygen deficiency atmosphere is defined as one with oxygen percent less
than?
20.5%
How many fires can be lit in a four story non-gas fire burn building?
1
______ should be interlocked with the fuel delivery valves to prevent fuel from
flowing with out confirmed pilot flame being present?
Pilot flames
Combustible gas detection should be provided in training and equipment spaces.
Such detection systems should be interlocked with the ventilation systems and
fuel delivery valves to shut down fuel flow and activate an external alarm when
the level exceeds
25% LEL
,Smoke used in training facility should be non-toxic and ?
Of known composition (Smoke used in the smoke building should be nontoxic and
of a known composition.)
_________________ is a structure acquired by the authority having jurisdiction
from property owner for purposes of conduct on live fire training evolutions?
Acquired Building
A training center burn building is a structure specifically designed for conducting
live fire training evolutions on a repetitive basis?
Live fire training structure
A_____________ is any student, instructor, safety officer, visitor, or other person
who is involved in a live fire training evolutions within the operation area ?
Participant
Is an individual appointed by the AHJ qualified to maintain a safe working
environment at all live fire evolutions?
Safety officer
, A__________ is any person who is present at a live fire training evolution for the
purpose of receiving training?
Student
Prior to being permitted to participate in live fire training evolutions the students
shall have received training to meet the minimum job performance requirements
for ?
Firefighter 1 NFPA 1001 (1403 4.3.1)
All hazardous structural conditions ______________ as to not present safety
problem during the use of the structure for live fire training evolution?
SHALL be Removed or repaired
Missing stair treads and rails SHALL be?
Shall be Repaired or replaced
Holes in walls and ceilings?
SHALL be patched