WhatvarevthevfourvlevelsvofvbiohazardvsafetyvbyvthevCDC?vAndvwhatvfactorsvinfluencevit?v-
vvCORRECTvANSWERSFour:vlevelsv1,v2,v3vandv4
Infectivity,vseverityvofvdisease,vtransmissibility,vandvnaturevofvworkvconductedvinvthevlab.
BiohazardvLevelv1v-vvCORRECTvANSWERS-MicrobesvinvBSL-
1vlabsvarevnotvknownvtovconsistentlyvcausevdiseasevinvhealthyvadultsvandvpresentvminimalvpotentialvhazar
dvtovlabvworkersvandvthevenvironment.vAnvexamplevofvavmicrobevthatvisvtypicallyvworkedvwithvatvavBSL-
1visvavnonpathogenicvstrainvofvEscherichiavcoli.
BiohazardvLevelv2v-vvCORRECTvANSWERS-MicrobesvinvBSL-
2vlabsvposevmoderatevhazardsvtovlabvworkersvandvthevenvironment.vThevmicrobesvarevtypicallyvindigenou
svandvassociatedvwithvdiseasesvofvvaryingvseverity.vAnvexamplevofvavmicrobevthatvisvtypicallyvworkedvwithv
atvavBSL-2vlaboratoryvisvStaphylococcusvaureus.
Biohazardvlevelv3v-vvCORRECTvANSWERS-MicrobesvinvBSL-
3vlabsvcanvbeveithervindigenousvorvexotic,vandvtheyvcanvcausevseriousvorvpotentiallyvlethalvdiseasevthroug
hvrespiratoryvtransmission.vRespiratoryvtransmissionvisvthevinhalationvroutevofvexposure.vOnevexamplevof
vavmicrobevthatvisvtypicallyvworkedvwithvinvavBSL-
3vlaboratoryvisvMycobacteriumvtuberculosis,vthevbacteriavthatvcausesvtuberculosis.
BiohazardvLevelv4v-vvCORRECTvANSWERS-MicrobesvinvBSL-
4vlabsvarevdangerousvandvexotic,vposingvavhighvriskvofvaerosol-
transmittedvinfections.vInfectionsvcausedvbyvthesevmicrobesvarevfrequentlyvfatalvandvwithoutvtreatmentv
orvvaccines.vTwovexamplesvofvmicrobesvworkedvwithvinvavBSL-
4vlaboratoryvincludevEbolavandvMarburgvviruses.
BiohazardvLevelv1vsafetyvproceduresv-vvCORRECTvANSWERS-Labvworkvisvperformedvatvavbench
-PersonalvProtectivevEquipmentv(PPE)vincludesvlabvcoat/apron,vgoggles,vandvglovesvwornvasvneeded
, -Sinkvisvavailablevforvhandvwashing
-Labvroomvshouldvbevseparatedvwithvavdoorvfromvthevrestvofvthevbuilding
BiohazardvLevelv2vsafetyvproceduresv-vvCORRECTvANSWERS-AllvrequirementsvforvBSL-1vplus:
-Accessvtovthesevlabsvisvrestrictedvtovapprovedvpersonnelvonly
-Labsvhavevselfvclosingvdoors
-Eyevwashvstation(s)varevavailable
-Anvautoclavevorvequalvmethodvofvsterilizationvisvavailable
BiohazardvLevelv3vsafetyvproceduresv-vvCORRECTvANSWERS-AllvrequirementsvforvBSL-2vplus:
-Personnelvmustvhavevnecessaryvvaccinations
-Workvisvperformvinvavbiohazardvsafetyvcabinet
-Airvsupplyvtovthevlabvroomvmustvbevdrawnvfromvavcleanvsupplyvandvcannotvbevrecirculated
-Labvroomvmustvhavevtwovselfvclosingvandvlockablevdoors.
BiohazardvLevelv4vsafetyvproceduresv-vvCORRECTvANSWERS-AllvrequirementsvforvBSL-3vplus:
-Personnelvmustvchangevclothingvandvshowervbeforevandvafterventeringvthesevlabs.
-BiosafetyvcabinetsvmustvbevavspecialvlevelvIIIvcabinet.
-Thevlaboratoryvisvlocatedvinvavseparatevbuildingvorvinvanvisolatedvandvrestrictedvzonevofvthevbuilding.
-
Thevlaboratoryvhasvdedicatedvsupplyvandvexhaustvair,vasvwellvasvvacuumvlinesvandvdecontaminationvsyste
ms.
WhatvtypesvofvlabsvarevplacedvinvUTA?v-
vvCORRECTvANSWERSThevMicrobiologyvLabsvatvUTAvarevconsideredvBSL-2
WhatvisvthevAsepticvtechnique?v-
vvCORRECTvANSWERSAsepticvtechniquevisvobtainedvbyvcreatingvavsterilevfieldvwithvavbunsenvburnervwhilev
performingvtests.vItvisvalsovimportantvtovensurevallvmedia,vreagents,vandvequipmentvarevproperlyvsterilize
dvbeforehandvbyvanvautoclavevsterilizer.
vvCORRECTvANSWERSFour:vlevelsv1,v2,v3vandv4
Infectivity,vseverityvofvdisease,vtransmissibility,vandvnaturevofvworkvconductedvinvthevlab.
BiohazardvLevelv1v-vvCORRECTvANSWERS-MicrobesvinvBSL-
1vlabsvarevnotvknownvtovconsistentlyvcausevdiseasevinvhealthyvadultsvandvpresentvminimalvpotentialvhazar
dvtovlabvworkersvandvthevenvironment.vAnvexamplevofvavmicrobevthatvisvtypicallyvworkedvwithvatvavBSL-
1visvavnonpathogenicvstrainvofvEscherichiavcoli.
BiohazardvLevelv2v-vvCORRECTvANSWERS-MicrobesvinvBSL-
2vlabsvposevmoderatevhazardsvtovlabvworkersvandvthevenvironment.vThevmicrobesvarevtypicallyvindigenou
svandvassociatedvwithvdiseasesvofvvaryingvseverity.vAnvexamplevofvavmicrobevthatvisvtypicallyvworkedvwithv
atvavBSL-2vlaboratoryvisvStaphylococcusvaureus.
Biohazardvlevelv3v-vvCORRECTvANSWERS-MicrobesvinvBSL-
3vlabsvcanvbeveithervindigenousvorvexotic,vandvtheyvcanvcausevseriousvorvpotentiallyvlethalvdiseasevthroug
hvrespiratoryvtransmission.vRespiratoryvtransmissionvisvthevinhalationvroutevofvexposure.vOnevexamplevof
vavmicrobevthatvisvtypicallyvworkedvwithvinvavBSL-
3vlaboratoryvisvMycobacteriumvtuberculosis,vthevbacteriavthatvcausesvtuberculosis.
BiohazardvLevelv4v-vvCORRECTvANSWERS-MicrobesvinvBSL-
4vlabsvarevdangerousvandvexotic,vposingvavhighvriskvofvaerosol-
transmittedvinfections.vInfectionsvcausedvbyvthesevmicrobesvarevfrequentlyvfatalvandvwithoutvtreatmentv
orvvaccines.vTwovexamplesvofvmicrobesvworkedvwithvinvavBSL-
4vlaboratoryvincludevEbolavandvMarburgvviruses.
BiohazardvLevelv1vsafetyvproceduresv-vvCORRECTvANSWERS-Labvworkvisvperformedvatvavbench
-PersonalvProtectivevEquipmentv(PPE)vincludesvlabvcoat/apron,vgoggles,vandvglovesvwornvasvneeded
, -Sinkvisvavailablevforvhandvwashing
-Labvroomvshouldvbevseparatedvwithvavdoorvfromvthevrestvofvthevbuilding
BiohazardvLevelv2vsafetyvproceduresv-vvCORRECTvANSWERS-AllvrequirementsvforvBSL-1vplus:
-Accessvtovthesevlabsvisvrestrictedvtovapprovedvpersonnelvonly
-Labsvhavevselfvclosingvdoors
-Eyevwashvstation(s)varevavailable
-Anvautoclavevorvequalvmethodvofvsterilizationvisvavailable
BiohazardvLevelv3vsafetyvproceduresv-vvCORRECTvANSWERS-AllvrequirementsvforvBSL-2vplus:
-Personnelvmustvhavevnecessaryvvaccinations
-Workvisvperformvinvavbiohazardvsafetyvcabinet
-Airvsupplyvtovthevlabvroomvmustvbevdrawnvfromvavcleanvsupplyvandvcannotvbevrecirculated
-Labvroomvmustvhavevtwovselfvclosingvandvlockablevdoors.
BiohazardvLevelv4vsafetyvproceduresv-vvCORRECTvANSWERS-AllvrequirementsvforvBSL-3vplus:
-Personnelvmustvchangevclothingvandvshowervbeforevandvafterventeringvthesevlabs.
-BiosafetyvcabinetsvmustvbevavspecialvlevelvIIIvcabinet.
-Thevlaboratoryvisvlocatedvinvavseparatevbuildingvorvinvanvisolatedvandvrestrictedvzonevofvthevbuilding.
-
Thevlaboratoryvhasvdedicatedvsupplyvandvexhaustvair,vasvwellvasvvacuumvlinesvandvdecontaminationvsyste
ms.
WhatvtypesvofvlabsvarevplacedvinvUTA?v-
vvCORRECTvANSWERSThevMicrobiologyvLabsvatvUTAvarevconsideredvBSL-2
WhatvisvthevAsepticvtechnique?v-
vvCORRECTvANSWERSAsepticvtechniquevisvobtainedvbyvcreatingvavsterilevfieldvwithvavbunsenvburnervwhilev
performingvtests.vItvisvalsovimportantvtovensurevallvmedia,vreagents,vandvequipmentvarevproperlyvsterilize
dvbeforehandvbyvanvautoclavevsterilizer.