Although there may be other reasons for using calcium tungstate screens in industrial
radiography, they are most usually used to:
A. Improve image contrast
B. Reduce film grain
C. Decrease exposure time (Correct)
D. Increase film resolution
Rationale: Calcium tungstate intensifying screens emit visible light that boosts film exposure,
allowing shorter exposure times.

In film radiography, penetrameters (penetrameters) are usually placed:
A. On the film side of the test object
B. On the source side of the test object (Correct)
C. Between film and cassette back
D. On the developer tray
Rationale: Penetrameters are placed on the source side to simulate a known thickness and
check technique.

The penetrating ability of an x-ray beam is primarily governed by:
A. Milliamperage (mA)
B. Kilovoltage (kV) (Correct)
C. Exposure time (s)
D. Focal spot size
Rationale: kV controls photon energy and thus beam penetrability.

Cobalt-60 used in nondestructive testing emits:
A. X-rays
B. Gamma rays (Correct)
C. Beta particles
D. Neutrons
Rationale: Co-60 is a gamma emitter used in industrial radiography.

A densitometer is an instrument for measuring:
A. Film thickness
B. Film density (Correct)
C. Radiation dose rate

,ESTUDYR


D. Grain size
Rationale: Densitometers quantify optical density on processed film.

Three liquids essential to properly process exposed film are:
A. Developer, fixer, and solvent
B. Fixer, water, and bleach
C. Developer, fixer, and water (Correct)
D. Developer, hardener, and solvent
Rationale: Standard manual processing uses developer, fixer, and thorough washing with
water.

The two most common causes for excessively high-density radiographs are:
A. Overdevelopment and underexposure
B. Overexposure and underdevelopment (Correct)
C. Low kV and small focal spot
D. Excessive filtration and short SFD
Rationale: Too much exposure or insufficient development control produce very dark films.

The time required for one-half of the atoms in a radioactive sample to disintegrate is called:
A. Decay constant
B. Half-life (Correct)
C. Activity
D. Curie
Rationale: Half-life is the standard term for radioactive decay half-time.

What does R/h refer to when speaking of intensity?
A. Rads per hour
B. Roentgens per hour (Correct)
C. Rems per hour
D. Röntgen-equivalents per hour
Rationale: R/h is an older unit indicating exposure rate in Roentgens per hour.

The ability to detect a small discontinuity or flaw is called:
A. Resolution
B. Radiographic sensitivity (Correct)
C. Contrast scale
D. DQE (detective quantum efficiency)
Rationale: Radiographic sensitivity describes the minimum detectable flaw size.

Movement, geometry, and screen contact are three factors that affect radiographic:
A. Contrast

, ESTUDYR


B. Density
C. Unsharpness (Correct)
D. Graininess
Rationale: These factors blur the recorded image and increase unsharpness.

The difference between the densities of two areas of a radiograph is called:
A. Latitude
B. Radiographic contrast (Correct)
C. Definition
D. Noise
Rationale: Contrast is the optical density difference that makes features distinguishable.

The most widely used unit for measuring rate of decay (activity) of a gamma source
historically is the:
A. Becquerel
B. Curie (Correct)
C. Gray
D. Sievert
Rationale: Curie is the traditional activity unit (Ci); SI unit is Becquerel (Bq).

Exposure to x-rays or gamma rays will have what effect on the body?
A. No cumulative effect with repeated low doses
B. It may have a cumulative effect which must be considered (Correct)
C. Only acute effects matter clinically
D. Radiation is harmless below any threshold
Rationale: Ionizing radiation can produce cumulative biological effects over time.

Which whole-body dose would be dangerous, if not fatal, if applied in a short period?
A. 1.5–15 R
B. 25–70 R
C. 200–800 R (Correct)
D. All of the above are fatal
Rationale: Acute whole-body doses in the hundreds of R (≈Gy) are potentially lethal.

When doing gamma-ray radiography with high-intensity emitters, sources are best handled:
A. With gloved hands and short exposure
B. By remote handling equipment (Correct)
C. Manually if shielded with lead aprons
D. By hand while wearing dosimeters only
Rationale: Remote handling reduces dose to personnel with high-activity sources.

Document information

Uploaded on
November 4, 2025
Number of pages
22
Written in
2025/2026
Type
Exam (elaborations)
Contains
Unknown
$18.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Estudyr
3.8
(222)
Sold
1222
Followers
830
Items
11234
Last sold
1 week ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions